3   Intended Use:

This product is made for changing voltages in home 

use like described in chapter 2. We do not permit 

using this product in other ways. Use the product only 

in dry interior rooms. If not attending to these regulations and 

notes on safety, it might causes fatal accidents, injuries and 

damages to persons and property. 

4  Scope of Delivery:

 

5  Installing and operating:

Installation:

1.  Turn off the mains fuse.

2.  Check with a voltage tester to be sure, all lines are really 

  stress-free. If in doubt, a electrician must do the installation 

  work.

3.  Check the packing content for being complete.

1 x voltage transformer

1 x user’s manual

DANGEr! risk of life by electric shock! 

Avoid contacting mains voltages!

Turn off the power of all circuits before working on the 

transformer!

ATTENTIoN! risk of short-circuit! 

Never bridge contacts!

Do not put things into ventilation slots or ports!

Summary of Contents for SET 12-06 LED slim

Page 1: ...Betriebsanleitung User s Manual Spannungstransformatoren VOLtage transformers SET 12 06 LED slim Art No 30000 SET 12 12 LED slim Art No 30001 SET 12 20 LED slim Art No 30002 SET 12 15 LED Art No 30005 ...

Page 2: ... und Demontage des Produkt gehäuses darf nur durch ausgebildetes Fachpersonal erfolgen Betriebsanleitung ACHTUNG Lesen Sie die Betriebsanleitung vollständig und sorgfältig durch Sie ist Bestandteil des Produktes und enthält wichtige Hinweise zur korrekten Installation und Benutzung Bewahren Sie sie auf damit Sie diese bei Unsicherheiten und Weitergabe des Produktes parat haben Spannungstransformat...

Page 3: ...Sonneneinstrahlung sowie Vibrationen und mechanischen Druck Modifizieren und ändern Sie weder Produkt noch Zubehörteile Beachten Sie dazu auch Kapitel Gewährleistung und Haftung Achten Sie beim Transport auf die im Kapitel Technische Daten gelisteten Angaben und treffen Sie geeignete Transport maßnahmen z B in der Originalverpackung Bei Fragen Defekten mechanischen Beschädigungen Störungen und and...

Page 4: ...umwandelt und z B in Möbeln verwendet werden kann Diese Transformatoren Serie zeichnet sich durch konstante Ausgangsspannung aus was Ihre LED Beleuchtung schont und deren Lebensdauer verlängert Weiterhin sind diese kurzschlusssicher überspannungsfest und haben nur einen minimalen Stand by Energiebedarf Transformatorgehäuse Klemmböcke Befestigungsschlitz Sekundärseite mit Abdeckkappe Anschluss der ...

Page 5: ... Unfällen und Schäden an Personen und Sachen führen 4 Lieferumfang 5 Installation und Bedienung Installation 1 Schalten Sie die Sicherung ab 2 Kontrollieren Sie mit einem Spannungsprüfer ob die zu 1 x Spannungstransformator 1 x Betriebsanleitung GEFAHR Lebensgefahr durch Stromschlag Vermeiden Sie den Kontakt mit Netzspannungen Schalten Sie vor Arbeiten am Spannungstransformator immer alle Stromkre...

Page 6: ...te Pol ist die Masse also negativ Der mit gekennzeichnete Pol ist der stromführende positive Pol 8 Schließen Sie Ihre LEDs in richtiger Polarität an die Klemm böcke im Sekundärkreis SEC 12 V DC an 9 Benutzen Sie einen Kabelquerschnitt von ca 0 75 mm Achten Sie darauf dass die Gesamtleistung der angeschlosse nen Leuchtmittel das Maximum des Spannungstransformators nicht übersteigt 9 Wenn alle Verbr...

Page 7: ...n Sie dabei auf stromführende Leitungen Setzen Sie keine Rei nigungsmittel oder Chemikalien ein da dies das Material angreifen kann Es darf keine Feuchtigkeit in das Produktin nere gelangen Vermeiden Sie Stellen mit hohen Temperaturen und Feuchtigkeit bzw Stellen die nass werden können auch bei Wartung Pflege Lagerung und Transport Lagern Sie Ihr Produkt bei längerem Nichtgebrauch für GEFAHR Leben...

Page 8: ...Kabel auf Funktion und schalten Sie nach fertiger Monta ge die Sicherung wieder ein Stellen Sie sicher dass die Verbrau cher für eine Gleichspannung von 12 V ausgelegt sind Der Transforma tor brummt oder erhitzt sich sehr stark Stellen Sie sicher dass die Maximal last nicht überschritten wird Lesen Sie hierzu Kapitel Technische Daten Nehmen Sie das Gerät außer Betrieb andere Fragen Konsultieren Si...

Page 9: ...cht in kg 0 036 0 054 Schutzart IP20 Modell 30002 30005 Eingangsspannung Primärseite 200 240 V AC Netzfrequenz Primärseite 50 Hz Ausgangsspannung Sekundärseite 12 V DC Einsatzbereich 0 5 20 W 0 5 15 W Standby Energie verbrauch k A Primär und Sekundärkabel H03VVH2 F 2x 0 75 mm Betriebstemperatur max 80 C Maße in mm 154 x 50 x 15 123 x 45 x 20 Gewicht in kg 0 094 0 058 Schutzart IP20 ...

Page 10: ...ich beschreiben nur dann haben Sie Gewähr dass auch selten auftretende Fehler mit Sicherheit gefunden und beseitigt werden Der Hersteller haftet nicht für Personen oder Sachschäden die durch unsachgemäße Installation Bedienung oder Wartung die nicht in dieser Anleitung beschrieben sind entstanden sind Ändern und modifizieren Sie das Produkt und dessen Zubehör nicht Ein anderer als in dieser Betrie...

Page 11: ...kung weist auf diese Bestimmungen hin Mit dieser Art der Stofftrennung Verwertung und Entsorgung von Altgeräten leisten Sie einen wichtigen Beitrag zum Schutz unserer Umwelt WEEE Richtlinie 2002 96 EG WEEE Nr 82898622 11CE Konformitätserklärung Dieses Gerät ist mit der nach der Richtlinie 2004 108 EG und 2006 95 EG vorgeschrie benen Kennzeichnung versehen Mit dem CE Zeichen erklärt Goobay eine reg...

Page 12: ...tion 21 1 Safety Instructions ATTENTION Only skilled electricians may assemble and disassemble the housing of the product ATTENTION Read the user s manual completely and carefully It is part of the product and includes important information for proper installation and use Keep this user s manual for clarification and only pass it on together with the product VOLTAGE transformers DANGER Risk of lif...

Page 13: ...e the product or its accessories Also mind chapter warranty and liability Mind the specifications for transporting and use applicable methods e g by using the original packing If defects mechanical damages disturbances or other problems occur which are not solvable with this manual take the device out of work immediately and consult your dealer for questions repairing or change like it is describe...

Page 14: ...series is characterized by constant output voltage what protects your LED lighting and prolonging their life Furthermore they come with short circuit protection overvolta ge protection and have only a minimal standby power consump tion transformer housing clamps mounting slot secondary side with cap Connection of the LED lighting primary side with cap Network connection ...

Page 15: ...of Delivery 5 Installing and Operating Installation 1 Turn off the mains fuse 2 Check with a voltage tester to be sure all lines are really stress free If in doubt a electrician must do the installation work 3 Check the packing content for being complete 1 x voltage transformer 1 x user s manual DANGER Risk of life by electric shock Avoid contacting mains voltages Turn off the power of all circuit...

Page 16: ...f the secondary circuit SEC 12 V DC 9 Use a cable cross section of about 0 75 mm Make sure that the overall performance of the connected lamps do not exceed the maximum supported voltage of the transfor mer 9 If all consumers are connected to the secondary side right connect the primary circuit PRI 200 240 V AC with its 2 clamps on to the electricity grid 10 Make sure all connections are tight 11 ...

Page 17: ...rials Avoid liquid entry to the device Avoid places with high temperatures humidity or places which can become wet also during maintenance care storage and transport Keep the product away from children and store it at dry and dust proof places Keep the original packing for transport and to avoid damages DANGER Risk of life by electric shock Avoid contacting mains voltages Turn off the power of all...

Page 18: ...e lamps are made for 12 V AC use The transformer hums or heats up very much Make sure of not overloading the maximum load Read chapter Specifi cations Take the transformer out of work other questions Consult your dealer 8 Specifications Model 30000 30001 Input voltage Primary side 200 240 V AC Mains frequency Primary side 50 Hz Output voltage Secondary side 12 V DC Application 0 6 W 0 12 W Standby...

Page 19: ... 0 75 mm operat temperatur max 80 C Dimensions in mm 154 x 50 x 15 123 x 45 x 20 Weight in kg 0 094 0 058 Protection class IP20 9 Warranty and Liability The producer grants a 2 years warranty to a new device As the manufacturer has no influence on installation warranty only applies to the product itself If any fault or damage is detected on your device please contact your dealer and provide your s...

Page 20: ...f the device packing or user s manual 10Disposal Notes According to the European WEEE directive electrical and electronic equipment must not be disposed with consumers waste Its components must be recycled or disposed apart from each other Otherwise contaminative and hazardous substances can pollute our environment You as a consumer are committed by law to dispose electrical and electronic devices...

Page 21: ...demark of the Wentronic GmbH ensures that the product is conformed to the basic standards and directives These standards can be requested online on www goobay de The mentioned directives replace all former national permissions in the European Union All trademarks and registered brands are the property of their respective owners ...

Page 22: ...22 User s Manual ...

Page 23: ...23 ...

Page 24: ...Revision Date 2012 01 13 Version 1 Goobay Pillmannstraße 12 38112 Braunschweig Germany Made in China Hotline 49 0180 5005882 E Mail info goobay de Web www goobay de ...