14
FS 250 B
15
SW 36
Danger: Down coming parts at the building site can cause injuries to the
operator!
Mounting the blade
Remove the toggle of the main switch in the control panel
before mounting the blade. Mount a blade with arbor
hole of 25.4 mm - 1 in. and a max. blade size of Ø 600
mm - 23.6 in. Check the correct rotation - arrows on the
blade and blade guard. Attach the blade guard.
1
2
Water supply
3
ON
OFF
Dashboard
3. Water pump ON-OFF
Using a GEKA-coupler connect the water supply to the floor saw coupler (1). Check the ball valve (2) is closed
(ball valve lever in 90°-position to the water flow) and the switch for the water pump (3) is in OFF-position.
Water supply from waterworks:
Open the ball valve (2) (ball valve lever in the water flow position)
Switch the water pump (3) in OFF-position
Water supply from water reservoir:
Open the ball valve (2) (ball valve lever in the water flow position)
Switch the water pump (3) in ON-position
Attention: Avoid dry-running of the water pump! Drain the water pump if frost
will appear!