Introduction ...........................................41
Index.....................................................41
...................................41
System characteristics ..............................42
System operation ....................................42
Important note........................................42
Definition ..............................................43
Minimum requirements............................43
Door panel ................................................
Installation ..........................................44
Configuration ......................................45
Final adjustments .................................46
Power supply installation ..........................47
Lock release installation ...........................47
Tekna R5 monitor ........................................
Description..........................................48
Function push buttons ...........................48
Safety precautions
End of line resistor.................................49
Monitor connection block description......49
Monitor installation...............................50
Programming.......................................51
T-730/R5 Telephone ...................................
Installation ..........................................52
Function push buttons ...........................52
Programming.......................................53
IMPORTANT considerations................54-55
Optional connections..................................
Parallel monitor or telephone .................56
External lock release activation...............56
Additional call repeater connection.........56
Installation diagrams..........................57-58
Troubleshooting hints ..............................59
Notes...............................................60-62
Compliance...........................................63
INTRODUCTION
INDEX
41
SYSTEM CHARACTERISTICS
SYSTEM OPERATION
42
O
O
O
O
O
O
O
O
w
w
O
Video door entry system with simple installation specially-designed to replace 4+n audio door
entry systems. Installation is done through 5 common wires
without independent call lines
.
IP-44 protection and IK-09 vandalproof door panel
.
Up to 3 door (access) panels which do not need switching units.
It's possible to use with coded general door panels (requires the use of the digital converter
CD-PLUS/R5
).
Acoustic busy channel and call acknowledgement signals.
Door opening timed at 3 seconds.
Alternate current lock release (see pg. 47).
With telephones T-730/R5:
Completely private conversation.
Output for connection to call repeater.
With monitors Tekna R5, in addition to the above features:
w
Privacy on audio and video communications.
w
'Video-Spy' function with the communication channel remaining free.
w
'Autoswitch-on' function.
w
Colour screen.
O
Possibility of 1 parallel monitor or telephone per apartment without additional power.
O
Does NOT require batteries for operation.
O
To make a call, the visitor should press the door panel push button: an acoustic tone will be heard
confirming the call is in progress once the push button has been pressed. At this moment the call will
be received at the monitor (telephone) in the dwelling.
O
In systems with several access doors, the other door panel(s) will be automatically disconnected: if a
visitor tries to call from another door panel an acoustic tone will be heard confirming the system is
busy.
O
The call tone will be reproduced on the monitor during 3 seconds: after this time the picture will
appear on the master monitor without the visitor being aware of this. To see the image on a
secondary monitor pick up its handset, disappearing the image on the other monitor. If the call is
not answered in 45 seconds, the system will be freed.
O
To establish communication pick up the monitor (telephone) handset.
O
The communication will last for one and a half minutes or until the handset is replaced. Once the
communication has finished the system will be freed.
O
To open the door, press the door release push button during call or communication progresses:
with one press, the door release operates during 3 seconds.
IMPORTANT NOTE
This system comes completely programmed to work with the included monitor. If
an extra monitor or telephone is required then it will need to be programmed
(pages 51 and 53).
SAFETY PRECAUTIONS
First of all we would like to thank and congratulate you for the purchase of this product manufactured by
Golmar.
The commitment to reach the satisfaction of our customers is stated through the ISO-9001 certification
and for the manufacturing of products like this one.
Its advanced technology and exacting quality control will do that customers and users enjoy with the
legion of features this system offers. To obtain the maximum profit of these features and a properly wired
installation, we kindly recommend you to expend a few minutes of your time to read this manual.
O
Install or modify the equipment
without the power connected
.
O
The installation and handling of these equipments must be performed by
authorised personnel
.
O
The entire installation must be at least
40 cm
. away from any
other installation
.
O
With power supply:
w
Do not use excessive force when tightening the connector screws.
w
Install the power supply in a dry and protected place without risk of drip or water projections.
w
Avoid to place it near to heating sources, in dusty locations or smoky enviroments.
w
Do not block ventilation holes of the unit so that air can circulate freely.
w
To avoid damage, the power supply has to be firmly fixed.
w
To avoid an electrical shock, neither remove the protection cover nor handle the connected wire in
the terminals.
O
With monitor, telephones and distributor:
Do not use excessive force when tightening the connector screws
w
.
w
Install the equipments in a dry and protected place without risk of drip or water projections.
w
Avoid to place it near to heating sources, in dusty locations or smoky enviroments.
w
Do not block ventilation holes of the equipments so that air can circulate freely.
O
Before to connect the system, check the connections between door panel, monitors and telephones,
and the transformer connection. Do always follow the enclosed information.
O
Each time the power supply is restarted, or after a modification, the system will remain blocked
during 45 seconds.