2
*
( )
PROGRAMMING THE DOOR PANEL
*
( )
*
( )
For more information, see the “TCODE/CA GB2 user manual (code 50122371)”
.
https://doc.golmar.es/search/manual/50122371
For more information, see the “TCODE/CA GB2 user manual (code 50122371)”
.
https://doc.golmar.es/search/manual/50122371
G 2
B AUDIO AND VIDEO DOOR ENTRY SYSTEM - PROXIMITY READER MODULE
G 2
B AUDIO AND VIDEO DOOR ENTRY SYSTEM - PROXIMITY READER MODULE
SAFETY PRECAUTIONS
-
Always disconnect the power supply
before installing or making modifications to the devices.
-
The fitting and handling of these devices must be carried out by
.
authorised personnel
-
The wiring must run at least
40 cm away from any other wiring.
-
Proximity key reader module and phone book navigation for GB2 coded door panel systems.
-
Can be combined with 'Nexa Modular' and 'Inox Modular' door panels.
-
Enables activation of the door release connected to Relay 1 of the EL632/GB2A module using the
proximity key reader.
-
Using the selection buttons, it enables the user to scroll through the phone book displayed on the
EL3422/GB2 TFT screen module and make a call by pressing the bell key.
CHARACTERISTICS
*
( )
DESCRIPTION OF THE MODULE
*
( )
a
b
e
f
a. Front.
b.
Proximity key reader.
c.
Bell button.
d.
Selection buttons.
e. Back.
f.
Socket for connection with the EL632/GB2A.
CONNECTION OF THE MODULE
*
( )
NA2
+
AP-
C1 NA1
AP+
C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
N3401/GB2
EL632/GB2A
c
d
(Step 2)
(Step 3)
With the EL632/GB2A module connected and operating, set its DIP
4 to the OFF position. (At the end of programming, it must be
returned to its initial position, ON for buildings/OFF for houses).
1 2 3
5 6
4
ON
Activating MASTER CARD keys on the door panel:
Using the DIP 4 located on the EL632/GB2A module, perform the following sequence:
1 2 3
5 6
4
ON
1 2 3
5 6
4
ON
1 2 3
5 6
4
ON
1 2 3
5 6
4
ON
ON
OFF
ON
OFF
At the end of the sequence, communication indicator and door open indicator will
illuminate. You then have 10 seconds to perform the following step.
Set the DIP 4 on the EL632/GB2A module to the initial position and remove the short
circuit between AP+ and AP-:
ON for buildings
OFF for houses
1 2 3
5 6
4
ON
1 2 3
5 6
4
ON
(Step 4)
Hold the MASTER CARD ADD key near to the proximity reader located on the
N3401/GB2 module and, once stored, communication indicator will turn off and
the door panel will emit a confirmation tone.
Then hold the MASTER CARD DELETE key near to the proximity reader located on
the N3401/GB2 module and, once stored, door open indicator will turn off and the
door panel will emit a confirmation tone.
(Step 5)
NA2
+
AP-
C1 NA1
AP+
Relay 2
Relay 1
_
12Vdc
The same MASTER CARD keys can be added to as many door panels as necessary.
Proximity keys for residents can then be added/deleted as indicated in the following section.
(Step 1)
NA2
+
AP-
C1 NA1
AP+
Relay 2
Relay 1
_
12Vdc
Cause a short circuit between the AP+ and AP-
terminals of Relay 1 on the EL632/GB2A module.
To the FA-GB2/A
power supply.
3