5

DESCRIPTION OF THE MONITOR

Function buttons:

(*)

In advanced programming mode, the default functions of function buttons

and

can be changed with one of the

following functions at the same time and per button:

'intercom,' 'auxiliary device A1 activation,' 'second camera 2C

activation' or 'call to secondary guard unit'

(see p. 13).

One long press for 2 seconds: with the monitor in standby and the handset on the hook, this activates

ringtone volume mode, with a tone indicating the volume selected. Then each long 2-second press
(before 5 seconds elapse) selects a volume level: maximum, no volume 'night mode,' minimum and
medium, and so on (carousel mode). Note: The 'night mode' status LED blinks red. During a call, the
monitor does not emit a ringtone unless it is an 'apartment front door call.'

One long press for 3 seconds: with the monitor in standby and the handset on or off the hook, this turns the

monitor off. Then one short 1-second press turns on the monitor. After any resetting of the monitor and for
the following 45 seconds, no operation with it can be performed.

One long press for 3 seconds during a call cancels the call on the monitor. If there are more monitors in the

apartment, they will continue with the ringtones of the door panel. During communication with the door
panel, the communication in progress will end.

With the monitor in standby and the handset off the hook, this activates the intercom function (in the same

apartment). One long press until a confirmation tone can be heard will call all of the monitors in the
apartment. To call individual devices, press the button once to call the 'master' monitor, twice to call 'slave
1,' 3 times to call 'slave 2,' 4 times to call 'slave 3' and 5 times to call 'slave 4.' This selective intercom call
mode is only available with Tekna Plus SE, Tekna HF Plus and Tekna S Plus monitors. This only functions
if no call or communication is in progress.

Regardless of the position of the handset, this activates auxiliary device 'A1.'

With the monitor in standby and the handset on the hook, this enables the image from the door panel

configured as main to be viewed (if the bus is busy, the status LED of the monitor will indicate so with a few
quick blinks). With the handset off the hook, this enables audio and video communication with door
panels that have their auto switch-on function activated to be established. This only functions if no
communication is in progress.

In call, a slave monitor enables the image of the door panel to be captured.

With the monitor in standby and the handset on the hook, this makes a panic call to the guard units

configured to receive such calls. With the handset off the hook, it enables a normal call to be made to the
main guard unit. During call reception and communication processes, it enables the lock release to be
activated.

( )

*

( )

*

TEKNA-S PLUS MONITOR

T

Communication with hearing aids:

The handset of the Tekna-S

monitor enables communication with hearing aids equipped with T-mode, making

Plus

conversation possible (inductive loop).

Remember:

Set the hearing aid switch to position T.

Summary of Contents for TEKNA-S PLUS

Page 1: ...Code 50122251 T S EN TEKNA PLUS REV 0219 USER MANUAL TEKNA S PLUS MONITOR TECHNOLOGY...

Page 2: ...ntained in this manual Introduction 2 Contents 2 Safety precautions 2 Characteristics 3 System operation 3 Description of the monitor 4 Description 4 Status LED and description of the connection termi...

Page 3: ...of the building being called and other possible general entrance door panels automatically disconnect If another visitor attempts to call from either a busy interior door panel a number of telephone...

Page 4: ...rvicio t cnico WARNING GOLMAR S A High Voltage Don t open cover C Silici 13 Handle only by technical service 08940 SPAIN ESCALERA STAIR PISO FLOOR PUERTA DOOR CN4 Handset 4 3 TFT colour screen Communi...

Page 5: ...ent One long press until a confirmation tone can be heard will call all of the monitors in the apartment To call individual devices press the button once to call the master monitor twice to call slave...

Page 6: ...ed as master slave and an address to be assigned Important This type of programming cannot be performed on a general entrance door panel To facilitate repair replacement or the addition of monitors to...

Page 7: ...at the back of the monitor on the right hand side To insert the EL 562S module first remove the jumper located in the CN4 connector and JP1 of the monitor NOTE In this type of installation set the SW...

Page 8: ...lugs supplied with the terminal Fixing the monitor s wall mounting connector to the wall Positioning the monitor 2 3 Avoid dusty or smoky environments or locations near sources of heat Connect the cab...

Page 9: ...f the monitor to the embedding box with the screws supplied Positioning the embedding box and fitting the wall mounting connector Positioning the monitor Avoid dusty or smoky environments or locations...

Page 10: ...for 1 second To show that the device is ready for programming the door panel and monitor will emit a number of tones the status LED on the monitor will illuminate red enabling door release button to...

Page 11: ...Important This type of programming cannot be performed on a general entrance door panel TEKNA S PLUS MONITOR To programme it as in call press button and the Slave without video status LED will blink g...

Page 12: ...ns the user to the first selection and 1 blink of the programming LED carousel mode Changing the ringtone melody Then select the melody for the ringtone selected in the previous step by pressing butto...

Page 13: ...all to secondary guard unit second camera 2C activation and intercom When the final selection is reached the following press returns the user to the first selection and 1 blink of the programming LED...

Page 14: ...the programming LED and in the following order 60 90 120 and 150 seconds When the final selection is reached the following press returns the user to the first selection and 1 blink of the programming...

Page 15: ...12 To exit programming mode press button for 3 seconds and the programming LED will turn off When exiting advanced programming mode the monitor will turn off Press button for 1 second to turn on the...

Page 16: ...A max SAR 12 24 F N IN IN NC NA C The neutral of the lighting power supply is arranged serially through the contacts of the SAR 12 24 relay and the maximum consumption of the element to be connected d...

Page 17: ...will emit a number of audible tones and an image will appear to establish communication with the door panel press button on the unit configured as master or press the door release button to simply ope...

Page 18: ...function button or on the monitor as described on p 13 To activate this function press the button configured for this function on the monitor during an auto spy call or communication process If the f...

Page 19: ...JP1 S S SW1 SW2 M Master M D Mesh Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5 CN3 DC lock release Video door entry system with coaxial cable Important For further information about the...

Page 20: ...s 2H JP1 A A D D CT Vpi Vd1 Mpi Md1 _ _ A D CT Vd6 Md6 _ A D Vpo Mpo _ D6L Plus 2H Vp Mp A D _ EL562S JP1 M Master D Mesh Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5 CN3 DC lock releas...

Page 21: ...21 TEKNA S PLUS MONITOR NOT S E...

Page 22: ...A 1 Este dispositivo no puede provocar interferencias da inas y 2 debe aceptar cualquier interferencia recibida incluyendo las que pueden provocar un funcionamiento no deseado Operation is subject to...

Reviews: