background image

12

ADVANCED PROGRAMMING (MONITOR FUNCTIONS)

To activate doctor mode: Press button

and the programming LED will indicate with 2 blinks

that the function is activated (the status LED will blink green) or with 1 blink that the function
is deactivated.

Advanced programming enables the monitor's default settings to be changed:

Turn off the monitor to be programmed (press button

for 3 seconds).

Once switched off, press button

to access

of advanced

'Menu 1'

programming and the programming LED will illuminate.

Then adjust the settings as required:

-

Activating/deactivating the doctor mode function:

Doctor mode not activated (default setting).

Select the ringtone to be changed: Each press on button

selects a ringtone which is

indicated with blinks (1 to 4 blinks) of the programming LED and in the following order: door
panel, guard unit, intercom call and 'HZ' apartment front door call. When the final selection
is reached, the following press returns the user to the first selection and 1 blink of the
programming LED (carousel mode).

-

Changing the ringtone melody:

Then select the melody for the ringtone (selected in the previous step) by pressing button

until

the required 'carousel mode' melody is heard.

The monitor has different ringtones to identify the origin of the call. The melodies assigned by default to the

ringtones can be selected from among others available on the monitor.

The 'doctor mode' function enables the lock release to be activated automatically 6 seconds after making a call

from the door panel without having to establish communication or press door release button

. The call ends

after 20 seconds and the channel will become free.

(Only the master monitor should be configured with 'doctor mode').

Men 1:

u

Advanced programming of the functions of the Tekna S Plus monitor:

Continued overleaf

-

Accessing 'Menu 2' or exiting programming mode:

To access

press button

and the programming LED will blink twice.

'Menu 2,'

To exit programming mode, press button

for 3 seconds, and the programming LED will turn

off (see p. 15).

TEKNA-S PLUS MONITOR

No function.

-

Button         has no function.

Summary of Contents for TEKNA-S PLUS

Page 1: ...Code 50122251 T S EN TEKNA PLUS REV 0219 USER MANUAL TEKNA S PLUS MONITOR TECHNOLOGY...

Page 2: ...ntained in this manual Introduction 2 Contents 2 Safety precautions 2 Characteristics 3 System operation 3 Description of the monitor 4 Description 4 Status LED and description of the connection termi...

Page 3: ...of the building being called and other possible general entrance door panels automatically disconnect If another visitor attempts to call from either a busy interior door panel a number of telephone...

Page 4: ...rvicio t cnico WARNING GOLMAR S A High Voltage Don t open cover C Silici 13 Handle only by technical service 08940 SPAIN ESCALERA STAIR PISO FLOOR PUERTA DOOR CN4 Handset 4 3 TFT colour screen Communi...

Page 5: ...ent One long press until a confirmation tone can be heard will call all of the monitors in the apartment To call individual devices press the button once to call the master monitor twice to call slave...

Page 6: ...ed as master slave and an address to be assigned Important This type of programming cannot be performed on a general entrance door panel To facilitate repair replacement or the addition of monitors to...

Page 7: ...at the back of the monitor on the right hand side To insert the EL 562S module first remove the jumper located in the CN4 connector and JP1 of the monitor NOTE In this type of installation set the SW...

Page 8: ...lugs supplied with the terminal Fixing the monitor s wall mounting connector to the wall Positioning the monitor 2 3 Avoid dusty or smoky environments or locations near sources of heat Connect the cab...

Page 9: ...f the monitor to the embedding box with the screws supplied Positioning the embedding box and fitting the wall mounting connector Positioning the monitor Avoid dusty or smoky environments or locations...

Page 10: ...for 1 second To show that the device is ready for programming the door panel and monitor will emit a number of tones the status LED on the monitor will illuminate red enabling door release button to...

Page 11: ...Important This type of programming cannot be performed on a general entrance door panel TEKNA S PLUS MONITOR To programme it as in call press button and the Slave without video status LED will blink g...

Page 12: ...ns the user to the first selection and 1 blink of the programming LED carousel mode Changing the ringtone melody Then select the melody for the ringtone selected in the previous step by pressing butto...

Page 13: ...all to secondary guard unit second camera 2C activation and intercom When the final selection is reached the following press returns the user to the first selection and 1 blink of the programming LED...

Page 14: ...the programming LED and in the following order 60 90 120 and 150 seconds When the final selection is reached the following press returns the user to the first selection and 1 blink of the programming...

Page 15: ...12 To exit programming mode press button for 3 seconds and the programming LED will turn off When exiting advanced programming mode the monitor will turn off Press button for 1 second to turn on the...

Page 16: ...A max SAR 12 24 F N IN IN NC NA C The neutral of the lighting power supply is arranged serially through the contacts of the SAR 12 24 relay and the maximum consumption of the element to be connected d...

Page 17: ...will emit a number of audible tones and an image will appear to establish communication with the door panel press button on the unit configured as master or press the door release button to simply ope...

Page 18: ...function button or on the monitor as described on p 13 To activate this function press the button configured for this function on the monitor during an auto spy call or communication process If the f...

Page 19: ...JP1 S S SW1 SW2 M Master M D Mesh Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5 CN3 DC lock release Video door entry system with coaxial cable Important For further information about the...

Page 20: ...s 2H JP1 A A D D CT Vpi Vd1 Mpi Md1 _ _ A D CT Vd6 Md6 _ A D Vpo Mpo _ D6L Plus 2H Vp Mp A D _ EL562S JP1 M Master D Mesh Vin Ain Aout Vin Vout Vout CN1 CV1 CV2 10 1 9 2 8 3 7 4 6 5 CN3 DC lock releas...

Page 21: ...21 TEKNA S PLUS MONITOR NOT S E...

Page 22: ...A 1 Este dispositivo no puede provocar interferencias da inas y 2 debe aceptar cualquier interferencia recibida incluyendo las que pueden provocar un funcionamiento no deseado Operation is subject to...