golmar T562 G2 Quick Manual Download Page 4

2

SAFETY PRECAUTIONS

-

Telephone with simplified wiring (non-polarised 2 wire bus).

-

Up to 4 telephones/monitors per apartment (master, slave 1, slave 2 and slave 3).

-

Up to 32 apartments/telephones per installation.

-

Up to 128 apartments/telephones per installation and maximum 1 telephone per apartment

(EL632

GB2A/EL642 GB2A sound module required)

.

-

Completely private conversation.

-

Call volume control (high, medium or mute).

-

Input for calls from the interior door of the apartment.

-

Call repeater output (SAR-12/24).

-

Different ringtones to identify the origin of the call (door panel, intercom or interior door of the

apartment).

-

Button

for lock release 1 activation.

-

Button         for intercom/lock release 2/light activation (SAR-GB2 and SAR-12/24 modules

required).

Important: Light activation function only with T-562 telephones V.03 and later.

-

Button for configuring ringtones (inside the telephone).

-

DIP switches for configuring telephone address (call code), master/slave and end of line and

activating 'doctor mode' function (inside the telephone).

-

Always disconnect the power supply

before making modifications to the device.

-

The fitting and handling of these devices must be carried out by

.

authorised personnel

-

The wiring must run at least

40 cm away from any other wiring.

-

Do not overtighten the screws on the connector.

-

Install the telephone in a dry protected location free from the risk of dripping or splashing water.

-

Do not place in humid, dusty or smoky locations, or near sources of heat.

-

Before connecting the device to the mains, check the connections between the door panel, power
supply and telephones.

-

Always follow the instructions contained in this manual.

CHARACTERISTICS

SYSTEM OPERATION

-

To make a call, the visitor needs to press the button for the apartment, an audible tone indicates

that the call is being made and LED

on the door panel illuminates. If vocal synthesis is enabled,

a 'Call is in progress' message appears indicating that a call is being made. At this moment, the
apartment's telephone(s) receives the call. If another apartment is called by mistake, press the
button for the correct apartment and the first call will be cancelled.

-

The call lasts for 40 seconds. If the call is not answered within 40 seconds, LED

will turn off and

the channel will be freed.

-

To establish communication, lift the handset of any telephone in the apartment and door panel

LED will illuminate.

-

Communication will last for one and a half minutes or until the handset is hung up. When
communication has finished, LEDs

and will turn off and the channel will be freed. If vocal

synthesis is activated, a 'Communication is finished' message will indicate that the call is over.

-

To open the door, press button

(if it exists and, to open the second door, press button

)

during the call or communication processes: one press activates the lock release for five
seconds and LED

on the door panel will also illuminate for five seconds. If vocal synthesis is

enabled, a 'Door Opened!' message will be indicated on the door panel.

-

Description of the function buttons can be found on p. 3.

*

( )

*

( )

For more information, see the T562 GB2 user manual (code 50121599).

https://doc.golmar.es/search/manual/50121599

3

DESCRIPTION OF THE TELEPHONE

*

( )

During call reception and communication processes, lock release 1 can be activated.

During call reception and communication processes, lock release 2 can be activated.
System in standby:

-

With the handset o

ff

the hook, it performs the intercom function.

-

With the handset on the hook, it activates the light function (SAR-GB2 and SAR-12/24 mod required).

.

Function buttons:

Call volume control:

*

( )

For more information, see the T562 GB2 user manual (code 50121599).

https://doc.golmar.es/search/manual/50121599

T562 G 2

B

TELEPHONE

T562 G 2

B

TELEPHONE

a

d

c

e

b

g

e

a.

b.

c.

d.

e.

Handset.
Speaker grille.
Microphone hole.
Subjection hole.
Telephone cord connector.

f

h

i

Door release button.
Hook switch

.

Auxiliary function button

.

Volume control.

f.

g.

h.

i.

MAX

OFF

The telephone has a call

volume control which can
be set to high, medium or
mute.

Description of DIP switches and configuration of telephone address (code):

*

( )

1

2

3

ON

E

: 0 + 0 + 4 +0+16 = 20

xample

Switch number:

1    2    3    4    5

1    2    4    8 16

Value when ON:

Table of values (DIP 10 to OFF)

4

5

6

DIP 1 to DIP 5:

Con

fi

gure telephone address (up to 32 addresses).

DIP 1 to DIP 7:

With DIP 10 set to ON, the telephone address can be con

fi

gured (up to 128 addresses).

The switches set to the OFF position have a value of zero.
The values of the switches set to ON are shown in the table below.
The telephone code is the sum of the values of the switches set to ON.

DIP 8 and DIP 9:

Con

fi

gure the telephone as master/slave. DIP 8 and DIP 9 to OFF master, DIP 8 to ON and DIP 9

to OFF slave 1, DIP 8 to OFF and DIP 9 to ON slave 2, DIP 8 and DIP 9 to ON slave 3. See function if DIP 10 to ON.

DIP 10:

Leave in the OFF position for installations of up to 32 telephones. Set to ON for installations of up to 128

telephones

and DIP 8 - DIP 9 without function, the telephone is always

(EL632GB2/EL642GB2 required)

'master' (max. 1 telephone per apartment).

DIP 11:

Con

fi

gures the end of line. In installations with telephones only, it must always be in the OFF position. In

mixed installations of monitors with telephones in the same apartment, set to ON for the telephones in which the
BUS cable ends and leave in the OFF position for intermediate telephones.

DIP 12:

Leaving it in the OFF position de

fi

nes the OFF position of the volume control switch as 'mute'.

Setting it to ON de

fi

nes the OFF position of the volume control switch as 'doctor mode'.

Description of connection terminals:

Bus connection.

Door bell connection.
Call repeater connection (SAR-12/24).
(12Vdc/50mA maximum).

L1  L2

,

:

HZ ,

:

SA , :

SA

L1 L2

_

HZ

_

_
_

7

8

9 10 11 12

Description:

1

2

3

ON

E

: 1 + 2 + 4 + 0 +0 +0+64 = 71

xample

Switch number:

1    2    3    4    5    6    7

: 1    2    4    8   16  32  64

Value when ON

Table of values (DIP 10 to ON)

4

5

6

7

8

9

10

11 12

Summary of Contents for T562 G2

Page 1: ...gado Evitar emplazamientos cercanos a fuentes de calor polvorientos o con mucho humo El tel fono puede fijarse en caja universal o directamente a pared Instalaci n con 32 viviendas tel fonos T562 GB2...

Page 2: ...durante los procesos de llamada o comunicaci n una sola pulsaci n activa el abrepuertas durante cinco segundos el led de la placa se iluminar tambi n durante cinco segundos Si la s ntesis de voz est...

Page 3: ...hook Avoid dusty or smoky environments or locations near sources of heat The telephone can be fixed to an electrical embedding box or directly to the wall Installation with 32 apartments T562 GB2 tele...

Page 4: ...r five seconds and LED on the door panel will also illuminate for five seconds If vocal synthesis is enabled a Door Opened message will be indicated on the door panel Description of the function butto...

Page 5: ...s d une source de chaleur de poussi res ou expos la fum e Le poste d appel peut tre install directement sur un mur Installation avec 32 habitations postes d appel T562 GB2 et g che lectrique de couran...

Page 6: ...i pendant cinq secondes Si la synth se vocale est habilit e le message ouverture de porte sera indiqu sur la plaque de rue Les poussoirs fonction des moniteurs sont d crits la page 3 Pour de plus ampl...

Page 7: ...2 Golmar latie met telefoons woningen en een 12Vdc deuropener Beldrukker paneel NA2 AP C1 NA1 AP C2 AP AP P1 P2 BUSBUS Rel 2 Rel 1 _ 12Vdc Deuropener m x 12 V c 270mA a d ON 1 2 3 4 5 6 AP SW1 VIVIEND...

Page 8: ...d zal de tekst de deur is geopend hoorbaar zijn De beschrijving van de functietoetsen bevindt zich op pagina 3 Voor meer informatie zie de handleiding T562 GB2 c d 50121599 https doc golmar es search...

Page 9: ...erosi o pieni di fumo Il telefono pu essere fissato in una scatola universale o direttamente a parete Installazione con 32 abitazioni telefoni T562 GB2 e serratura elettrica in corrente continua Golma...

Page 10: ...omunicazione premendo una sola volta la serratura elettrica si attiver per cinque secondi e anche il led della pulsantiera si illuminer per cinque secondi Se abilitata la sintesi vocale apparir il mes...

Page 11: ...fontes de calor pulverulentos ou com muito fumo O telefone pode ser fixado em caixa universal ou diretamente na parede Instala o com 32 habita es telefones T562 GB2 e trinco el trico de corrente cont...

Page 12: ...de chamada ou comunica o uma prem ncia ativa o trinco el trico durante 5 segundos o da placa acende se tamb m durante 5 segundos Se a led s ntese de voz estiver ativada a mensagem porta aberta ser in...

Reviews: