2
SAFETY PRECAUTIONS
-
Telephone with simplified wiring (non-polarised 2 wire bus).
-
Up to 4 telephones/monitors per apartment (master, slave 1, slave 2 and slave 3).
-
Up to 32 apartments/telephones per installation.
-
Up to 128 apartments/telephones per installation and maximum 1 telephone per apartment
(EL632
GB2A/EL642 GB2A sound module required)
.
-
Completely private conversation.
-
Call volume control (high, medium or mute).
-
Input for calls from the interior door of the apartment.
-
Call repeater output (SAR-12/24).
-
Different ringtones to identify the origin of the call (door panel, intercom or interior door of the
apartment).
-
Button
for lock release 1 activation.
-
Button for intercom/lock release 2/light activation (SAR-GB2 and SAR-12/24 modules
required).
Important: Light activation function only with T-562 telephones V.03 and later.
-
Button for configuring ringtones (inside the telephone).
-
DIP switches for configuring telephone address (call code), master/slave and end of line and
activating 'doctor mode' function (inside the telephone).
-
Always disconnect the power supply
before making modifications to the device.
-
The fitting and handling of these devices must be carried out by
.
authorised personnel
-
The wiring must run at least
40 cm away from any other wiring.
-
Do not overtighten the screws on the connector.
-
Install the telephone in a dry protected location free from the risk of dripping or splashing water.
-
Do not place in humid, dusty or smoky locations, or near sources of heat.
-
Before connecting the device to the mains, check the connections between the door panel, power
supply and telephones.
-
Always follow the instructions contained in this manual.
CHARACTERISTICS
SYSTEM OPERATION
-
To make a call, the visitor needs to press the button for the apartment, an audible tone indicates
that the call is being made and LED
on the door panel illuminates. If vocal synthesis is enabled,
a 'Call is in progress' message appears indicating that a call is being made. At this moment, the
apartment's telephone(s) receives the call. If another apartment is called by mistake, press the
button for the correct apartment and the first call will be cancelled.
-
The call lasts for 40 seconds. If the call is not answered within 40 seconds, LED
will turn off and
the channel will be freed.
-
To establish communication, lift the handset of any telephone in the apartment and door panel
LED will illuminate.
-
Communication will last for one and a half minutes or until the handset is hung up. When
communication has finished, LEDs
and will turn off and the channel will be freed. If vocal
synthesis is activated, a 'Communication is finished' message will indicate that the call is over.
-
To open the door, press button
(if it exists and, to open the second door, press button
)
during the call or communication processes: one press activates the lock release for five
seconds and LED
on the door panel will also illuminate for five seconds. If vocal synthesis is
enabled, a 'Door Opened!' message will be indicated on the door panel.
-
Description of the function buttons can be found on p. 3.
*
( )
*
( )
For more information, see the T562 GB2 user manual (code 50121599).
https://doc.golmar.es/search/manual/50121599
3
DESCRIPTION OF THE TELEPHONE
*
( )
During call reception and communication processes, lock release 1 can be activated.
During call reception and communication processes, lock release 2 can be activated.
System in standby:
-
With the handset o
ff
the hook, it performs the intercom function.
-
With the handset on the hook, it activates the light function (SAR-GB2 and SAR-12/24 mod required).
.
Function buttons:
Call volume control:
*
( )
For more information, see the T562 GB2 user manual (code 50121599).
https://doc.golmar.es/search/manual/50121599
T562 G 2
B
TELEPHONE
T562 G 2
B
TELEPHONE
a
d
c
e
b
g
e
a.
b.
c.
d.
e.
Handset.
Speaker grille.
Microphone hole.
Subjection hole.
Telephone cord connector.
f
h
i
Door release button.
Hook switch
.
Auxiliary function button
.
Volume control.
f.
g.
h.
i.
MAX
OFF
The telephone has a call
volume control which can
be set to high, medium or
mute.
Description of DIP switches and configuration of telephone address (code):
*
( )
1
2
3
ON
E
: 0 + 0 + 4 +0+16 = 20
xample
Switch number:
1 2 3 4 5
1 2 4 8 16
Value when ON:
Table of values (DIP 10 to OFF)
4
5
6
DIP 1 to DIP 5:
Con
fi
gure telephone address (up to 32 addresses).
DIP 1 to DIP 7:
With DIP 10 set to ON, the telephone address can be con
fi
gured (up to 128 addresses).
The switches set to the OFF position have a value of zero.
The values of the switches set to ON are shown in the table below.
The telephone code is the sum of the values of the switches set to ON.
DIP 8 and DIP 9:
Con
fi
gure the telephone as master/slave. DIP 8 and DIP 9 to OFF master, DIP 8 to ON and DIP 9
to OFF slave 1, DIP 8 to OFF and DIP 9 to ON slave 2, DIP 8 and DIP 9 to ON slave 3. See function if DIP 10 to ON.
DIP 10:
Leave in the OFF position for installations of up to 32 telephones. Set to ON for installations of up to 128
telephones
and DIP 8 - DIP 9 without function, the telephone is always
(EL632GB2/EL642GB2 required)
'master' (max. 1 telephone per apartment).
DIP 11:
Con
fi
gures the end of line. In installations with telephones only, it must always be in the OFF position. In
mixed installations of monitors with telephones in the same apartment, set to ON for the telephones in which the
BUS cable ends and leave in the OFF position for intermediate telephones.
DIP 12:
Leaving it in the OFF position de
fi
nes the OFF position of the volume control switch as 'mute'.
Setting it to ON de
fi
nes the OFF position of the volume control switch as 'doctor mode'.
Description of connection terminals:
Bus connection.
Door bell connection.
Call repeater connection (SAR-12/24).
(12Vdc/50mA maximum).
L1 L2
,
:
HZ ,
:
SA , :
SA
L1 L2
_
HZ
_
_
_
7
8
9 10 11 12
Description:
1
2
3
ON
E
: 1 + 2 + 4 + 0 +0 +0+64 = 71
xample
Switch number:
1 2 3 4 5 6 7
: 1 2 4 8 16 32 64
Value when ON
Table of values (DIP 10 to ON)
4
5
6
7
8
9
10
11 12