4
*
( )
T562 G 2
B
TELEPHONE
Code
501215
Web
99
T
G 2 EN
562 B
GR
REV.0 1
2 7
Golmar se reserva el derecho a cualquier modificación sin previo aviso.
Golmar se réserve le droit de toute modification sans préavis .
Golmar reserves the right to make any modifications without prior notice.
QUICK GUIDE
www.golmar.es
Sistemas de comunicación S.A.
T562 G 2
B
TELEPHONE
INSTALLING THE TELEPHONE
*
( )
Open the telephone by inserting a flat
screwdriver into the slots and gently pry open
as shown in the drawing.
To fix directly to the wall, drill two 6mm holes at the
specified positions and use 6mm wall plugs and
Ø3.5 x 25mm screws.
Pass the cables through the cable holes and connect
them to the connector. Close the telephone as shown
in the drawing. Once the telephone is closed, connect
the handset using the telephone cord and place it on
the hook.
Avoid dusty or smoky environments or locations near sources of heat. The telephone can be
fixed to an electrical embedding box or directly to the wall.
Installation with 32 apartments/T562 GB2 telephones and Golmar DC lock release.
Button panel
NA2
+
AP-
C1 NA1
AP+
C2 AP+ AP- P1 P2 BUSBUS
Relay 2
Relay 1
_
12Vdc
Lock release
max. 12 Vdc/270mA.
ON
1 2 3 4 5 6
AP
SW1
APARTMENT
1
Twisted pair 2x0.75mm
2
Twisted pair 2x1mm
2
60m
A
60m
B
80m 80m
Cable
10m
C
15m
*
( )
*
( )
WIRING DIAGRAM
APARTMENT
32
Distances and cross-sections:
T562
A
C
B
L1 L2
T-562 GB2
L1 L2
T-562 GB2
Master
Master
For more information, see the T562 GB2 user manual (code 50121599).
https://doc.golmar.es/search/manual/50121599
*
( )
T562
50121895
FA-
2
GB /A
Mains
100~240Vac
N
L
CN
BUS (M) BUS(PL)
FA-
2
GB /A
L
IMPORTANT:
With a coded panel system
, an EL632
GB2A/EL642 GB2A sound module is required and must be
set to 'operating mode 5'
(See corresponding door panel manual).
1
( )
( )
Access panel
or
Coded panel
Button building
mode
or
Coded building
mode
IMPORTANT: Set the DIP
switches as shown in the
diagram.
1
( )