background image

10

9

To

 the 1

st

 push b. or to the P terminal of the 1

st

 EL516.

To

 the next push b. or to the P terminal of the 2

nd

 EL516.

To

 the next push b. or to the P terminal of the 3

rd

 EL516.

To

 the next push b. or to the P terminal of the 4

th

 EL516.

To

 the next push b. or to the P terminal of the 5

th

 EL516.

To

 the next push b. or to the P terminal of the 6

th

 EL516.

To

 the next push b. or to the P terminal of the 7

th

 EL516.

To

 the last push b. or to the P terminal of the 8

th

 EL516.

To

 the

 push

 b.

 common

 terminal

 and

 to

 the

 EL516

 CP

 terminal.

To

 the

 B

 terminal

 of

 the

 EL516

 encoders.

ush buttons limit.

P

ush buttons digital code.

P

ush buttons wiring

.

P

The enclosed drawing shows an example of connection between the EL500 circuit and two

     EL516 with their corresponding push buttons.

The codes shown on the first column (shadowed) correspond with the push buttons

     directly connected to the corresponding terminal on the CN2 terminal connector

     of the EL500 circuit, or with the terminal 1 of its corresponding EL516 encoder

.

The maximum number of push buttons to be connected depends on the number of installed

     EL516 encoders, as it is shown on the following chart:

          W

ithout EL516 circuits:

          W

ith 1 EL516 circuit:

          W

ith 2 EL516 circuits:

          W

ith 3 EL516 circuits:

          W

ith 4 EL516 circuits:

          W

ith 5 EL516 circuits:

          W

ith 6 EL516 circuits:

          W

ith 7 EL516 circuits:

          W

ith 8 EL516 circuits:

8

7 + 15 = 22

6 + 15 + 15 = 36

5 + 15 + 15 +15 = 50

4 + 15 + 15 + 15 +15 = 64

3 + 15 + 15 + 15 +15 + 15 = 78

2 + 15 + 15 + 15 +15 + 15 + 15 = 92

1 + 15 + 15 + 15 +15 + 15 + 15 + 15 = 106

0 + 15 + 15 + 15 +15 + 15 + 15 + 15 +15 = 120

To

 other

encoders

or

push buttons

1

P2

1

P1

31

P4

61

P6

91

P8

16

P3

46

P5

76

P7

106

2

2

32

62

92

17

47

77

107

3

3

33

63

93

18

48

78

108

4

4

34

64

94

19

49

79

109

5

5

35

65

95

20

50

80

110

6

6

36

66

96

21

51

81

111

7

7

37

67

97

22

52

82

112

8

8

EL516 terminals

EL500terminals

38

68

98

23

53

83

113

9

9

39

69

99

24

54

84

114

10

10

40

70

100

25

55

85

115

11

11

41

71

101

26

56

86

116

12

12

42

72

102

27

57

87

117

13

13

43

73

103

28

58

88

118

14

14

44

74

104

29

59

89

119

15

15

45

75

105

30

60

90

120

DOOR P

ANEL INST

ALLA

TION

DOOR P

ANEL INST

ALLA

TION

In case to combine these door panels with coded door panels or porter's exchange

     it will be necessary to know these codes for a properly system configuration.

P8

P7

P6

CN2

P5

P4

P3

P2

P1

CP
B

P8

P7

P6

P5

P4

P3

P2

P1

CP
B

CN2

22

33

44

55

66

77

88

99

10

10

11

11

12

12

13

13

14

14

15

15

PP

CP

CP

11

BB

The

 CN2

 connector

 of

 the

 EL500

 microprocessed

 circuit

 has

     8

 terminals

 (P1

 to

 P8)

 for

 the

 connection

 of

 push

 buttons

     or

 EL516

 encoders.

 The

 CP

 terminal

 of

 the

 EL500

 circuit

     must

 be

 connected

 to

 the

 push

 buttons

 common

 terminal

     and

 to

 the

 CP

 terminal

 of

 the

 push

 buttons

 encoders.

     Connect

 B

 terminal

 to

 the

 B

 terminal

 of

 the

 encoders.

Summary of Contents for T500EN

Page 1: ...Stadio Plus T500EN rev 0205 Instructions manual Audio and Video door entry system digital installation...

Page 2: ...and a half minutes or until the handset is replaced Once the communication has finished the system will be freed O To open the door press the door release push button during call or communication prog...

Page 3: ...the door panel should be placed at 1 65m height roughly The hole dimensions will depend on the number of door panel modules The door panel has been designed to be placed under most of the environmenta...

Page 4: ...marked in the lower module and fix it by screwing the module shafts Place the module spacer between lower and next modules assuring that the spacer adjustment notches are inside the panel Fix the modu...

Page 5: ...on the embedding box insert the hinges in the embedding box lockers as shown old the door panel on the embedding box H For a quality finish pass the push buttons wires through the spacer hole of the...

Page 6: ...L516 circuits With 5 EL516 circuits With 6 EL516 circuits With 7 EL516 circuits With 8 EL516 circuits 8 7 15 22 6 15 15 36 5 15 15 15 50 4 15 15 15 15 64 3 15 15 15 15 15 78 2 15 15 15 15 15 15 92 1 1...

Page 7: ...installations the EL562 module must be plugged in all the monitors and JP2 jumper of the EL500 circuit must be placed on the position specified on page 11 Refer to the specific installation diagram es...

Page 8: ...ts in case of a FA Plus model Link power supplies to connect more units than the specified as it s shown on page 24 The power supply must be installed in a dry and protected place It s recommended to...

Page 9: ...Floor Door Stair PLATEA Plus 0000000000 N serie a f g b e j l k m d i c h a b c d e f g h i j k l m Handset B W or color screen depending on the model Front film Function push buttons Cord Attachment...

Page 10: ...onal device activation output twisted pair video signal Vin Malla Vout A D HZ INT SA CTO 2C A1 Vp Mp L562 module for video installations E with twisted pair cable andling the end of line jumper H hang...

Page 11: ...e In systems with more than one door panel the programming process shall be done on the master door panel only Switch off the monitor to be programmed Once the monitor is off press the door release pu...

Page 12: ...allows to call to the master porter s exchange During call reception and communication progresses allows the lock release activation a b c a b c erminal connector description Tpositive ground audio di...

Page 13: ...es both monitors or telephones Make a call to check that the telephone has been succesfully programmed Repeat these steps to program the rest of telephones Once the programming has been finished set t...

Page 14: ...e first distributor INSTALLATION DIAGRAMS ideo installation with coaxial cable v The installation diagram shows the connection of a video system with one or several door panels for the same building I...

Page 15: ...CTIONS CHART 50m Distance 150m A A A D in out V V V M in out p d p d CV CV INSTALLATION DIAGRAMS ideo installation without coaxial cable v The installation diagram shows the connection of a video syst...

Page 16: ...tion A 1 00mm 2 50mm 0 25mm 0 25mm Terminal SECTIONS CHART 50m Distance 150m A A A D in out CV CV Place this power supply as closest as possible to the first telephone The installation diagram shows t...

Page 17: ...SCART connector it will be possible to view the picture from the door panel on the TV screen Remove the end of line jumper that s placed on the CN4 connector Connect the coaxial cable between terminal...

Page 18: ...s with the exception of a shortcircuit between CTO and monitor or distributor terminals O Nothing operates w Check the output power supply voltage between and terminals it should have 17 5 to 18 5Vd c...

Page 19: ...el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior notice golmar golma...

Reviews: