background image

ACCESS CONTROL DESCRIPTION

5

4

ACCESS CONTROL PROGRAMMING

DOOR PANEL INSTALLATION

lace the nameplate labels.

P

Open the label holder.

Place the label and
     close.

inal adjustments.

F

If after starting the system it's considered that the audio
     volume isn't correct, proceed with the necessary
     adjustments as shown.

Once the nameplate labels are placed, wire the
     lamps from different modules and connect them
     to terminals L1 and L2 of the sound module,
     as it's shown on the installation diagrams.

lose the door panel.

C

Fix the door panel by using the supplied
     screws.

Finish the door panel assembly by pressing
     the closing heads.

rogramming methodes.

P

It will be necessary to enter into the programming menu to configure the system properties.
     Two different programming menues are available: 

installer

, that allows to modifiy any of the

     system properties and 

user

, that only allows to change the relay activation codes,

     the user code and to disable the keypad acknowledgement signal.

Programming options with black text and white background are availables in both menues;
     options with white text and black background are only availables on installer menu.

The module will automatically exit from the configuration menu after 2 minutes with no operation.

Installation terminal connector is located on the rear
     part of the module. The correspondance of each
     terminal is as follows:

Jumper JP4, that's placed on the left side of the terminal connector
     allows to reset the installer PIN code to the factory default
     (see page 6).
     Use this function only in case to forget this code.
     With the system switched on, change the jumper position
     to reset the code and return it to the standby position.

odule description

M

power supply input.
positif for battery.
negatif for battery.
relay 1 common terminal.
relay 1 output terminal.
relay 2 normally closed output.
relay 2 common terminal.
relay 2 normally closed output.
panic output.

~, ~ :
B+ :
B–  :
C1 :
N1 :
NC2 : 
C2 :
NA2 :
P :

Reset.

Standby.

Summary of Contents for Stadio Plus 4113/AL

Page 1: ...Audio door entry system Kits with access control Stadio Plus T4003EN rev 0105 Instructions manual...

Page 2: ...acturing of products like this one Its advanced technology and exacting quality control will do that customers and users enjoy with the legion of features this system offers To obtain the maximum prof...

Page 3: ...dule has been designed to be placed under most of the environmental conditions However it s recommended to take additional cautions like rainproof covers DOOR PANEL INSTALLATION Break the bottom flang...

Page 4: ...ws to change the relay activation codes the user code and to disable the keypad acknowledgement signal Programming options with black text and white background are availables in both menues options wi...

Page 5: ...e of the function under programming Once the value has been entered the module will reproduce a 4 slow acoustic tones Enter the next function field to be programmed or press key symbol to exit from th...

Page 6: ...7 8 1 2 3 4 5 6 7 8 1 1 2 2 2 2 2 2 2 2 Continue Coming from previous page unction fields and values F It defines the activation code of the panic function Proceed as detailed on 11 field 0 3 It defin...

Page 7: ...lock releases simultaneously the maximum load of this power supply must be calculated If necessary an additional power supply can be used to activate these devices The connection of an additional TF...

Page 8: ...in case of a valid code three acoustic tones will be reproduced and the lock release will be activated In case of a wrong code a long acoustic tone will be heard w w After introduction of three conse...

Page 9: ...digits 2nd code Relay 1 2nd code Relay 2 3rd code Relay 1 3rd code Relay 2 4th code Relay 1 4th code Relay 2 5th code Relay 1 5th code Relay 2 6th code Relay 1 6th code Relay 2 7th code Relay 1 7th c...

Page 10: ...dback fade out O Door open function no operates w Disconnect the lock release from the sound module and short circuit terminals and P at that moment the output voltage between terminals CV and 2 of th...

Page 11: ...el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior notice golmar golma...