Configuration switches (R)
Configuration changes must be made with the equipment switched off. If they are carried out with the equipment
on, disconnect it for 10 seconds after any modification.
All switches are factory-set to the OFF position.
Switch 1.
Sets the door panel address.
OFF
* OFF-OFF
OFF
ON
ON-OFF
ON
Door panel 1
Door panel 2
1 apartment
* Same value than when set to ON-ON.
Enabled
2 apartments
Disabled
Switches 2 and 3.
Set the number of apartments:
1: all push buttons call to apartment n.1.
2: the two lower push buttons call to apartment n.1,
the two upper push buttons call to apartment n.2.
4: each push button calls to a different apartment (n.1 to 4).
Switch 4.
Disables door panel acoustic tones.
OFF-ON
4 apartments
Audio level adjustment
If after the start-up of the system you consider that the audio volume on the door panel is not suitable, use the
adjustment potentiometer (S). This regulation affects the audio level of the communication and that of the
confirmation tones.
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
ON
1
2
3
4
SOUL S5110/ART 7W VIDEO INTERCOM KIT
SOUL DOOR PANEL
BUS
BUS
CV-
CV+
AP+
C
NA
GND CCTV AP-
ON
1
2
3
4
All manuals and user guides at all-guides.com