background image

OPTIONAL CONNECTIONS

Intercom between two points in the same apartment:

The NHEA Plus SE terminal features as standard an intercom function between two points in the same apartment.

To enable this function, the following is necessary:

-

One of the terminals needs to be configured as master and the other as slave with intercom, as described on
p. 8. In the case of intercom between a monitor and a terminal, it is recommended to configure the monitor as
the master.

-

The INT terminal of the intercom devices needs to be connected (see diagram attached).

-

Changing the function of button

by default with activation of aux devices 'A1' for 'intercom' (see p. 10).

To use the intercom function, enter function mode (press button

for 1 second), then press and hold button

until

you hear a confirmation tone call all of the terminals in the apartment. To call individual devices, press the button
once to call the 'master' terminal, twice to call 'slave 1', 3 times to call 'slave 2', 4 times to call 'slave 3' and 5 times to
call 'slave 4'. This selective intercom call mode is only available with the Plus SE terminal, telephone and monitor.
This only functions if no call or communication is in progress. A number of audible tones emitted by the terminal will
confirm that the call is being made or that the unit being called is in communication with the door panel. To establish
communication, press button

of the unit being called. If a call is received from the door panel during an intercom

process, the terminal of the master unit will emit a number of audible tones. To establish communication with the
door panel, press button

on the unit configured as master or press the door release button to simply open the

door.

The ringtones vary depending on where the call is being made from, enabling the user to identify its origin.

Note:

If the apartment also has T-540 Plus telephones, the NHEA Plus SE terminals must be configured as

'Intercom with Plus telephones/monitors' (see p. 9). This configuration mode does not allow selective intercom
calls to different terminals/telephones in the apartment; when the intercom button is pressed, all of the
terminals/telephones in the apartment will receive the call.

Continued overleaf

Continued from previous page.

A

+ _

D

A

+ _

D

13

NHEA PLUS SE HANDS-FREE AUDIO TERMINAL

NHEA Plus SE

AUX

NHEA Plus SE

AUX

5  4  3  2  1

CN2

5  4  3  2  1

CN2

INT (Red)

Summary of Contents for NHEA PLUS SE TERMINAL

Page 1: ...Code 50123372 TNHEA EN PLUS SE REV 0219 NHEA PLUS SE TERMINAL USER MANUAL PLUS DIGITAL SYSTEM...

Page 2: ...he mains check the connections between the door panel power supply and terminals Always follow the instructions contained in this manual Introduc 2 tion Contents 2 Safety precautions 2 Characteristics...

Page 3: ...and other possible general entrance door panels automatically disconnect If another visitor attempts to call from either a busy interior door panel a number of telephone tones will indicate that the c...

Page 4: ...een master Nhea terminal Communication LED illuminated green Night mode LED blinking red Doctor mode LED blinking green Function buttons Audio volume control switch Ringtone volume control switch g h...

Page 5: ...en each long 3 second press before 5 seconds elapse selects a ringtone volume level and so on in carousel mode with the following selections maximum minimum and no volume night mode Note The night mod...

Page 6: ...plugs supplied with the terminal Fixing the terminal s wall mounting connector to the wall Positioning the terminal 1 2 3 Avoid dusty or smoky environments or locations near sources of heat x 4 30 Con...

Page 7: ...or of the terminal to the embedding box with the screws supplied Positioning the embedding box and fitting the wall mounting connector Positioning the terminal Avoid dusty or smoky environments or loc...

Page 8: ...not done the door panel will emit tones to indicate that the system is still in programming mode M S SI Turn off the terminal to be programmed press button for 3 seconds Once switched off press the d...

Page 9: ...he doctor mode function Doctor mode not activated default setting The doctor mode function enables the lock release to be activated automatically 10 seconds after making a call from the door panel wit...

Page 10: ...to 3 blinks of the status LED and in the following order 1 2 or 3 repeats When the final selection is reached the following press returns the user to the first selection and the status LED blinks onc...

Page 11: ...No function Button has no function Accessing Menu 1 or exiting programming mode When exiting advanced programming mode the terminal will be turned off Press button for 1 second to turn the terminal b...

Page 12: ...ly through the contacts of the SAR 12 24 relay and the maximum consumption of the element to be connected does not exceed 1 8A Vac lock release T 104 F Mains PRI SEC SAR 12 24 IN IN NC NA C Important...

Page 13: ...SE terminal telephone and monitor This only functions if no call or communication is in progress Anumber of audible tones emitted by the terminal will confirm that the call is being made or that the u...

Page 14: ...partment front door This feature precludes the need to use the bell by positioning a switch between terminals HZ and of the terminal The ringtones vary depending on where the call is being made from e...

Page 15: ...mar es search manual 50122328 FA Plus C or FA Plus SEC PRI Mains Place this power supply as close as possible to the first terminal A A _ _ D D A _ D A _ D Access panel M Master D Mesh Vin Ain Aout Vi...

Page 16: ...olmar se reserva el derecho a cualquier modificaci n sin previo aviso Golmar se r serve le droit de toute modification sans pr avis Golmar reserves the right to make any modifications without prior no...

Reviews: