T-ART/G2+ TELEPHONE DESCRIPTION:

Funtion push button:

Descrip i n:

t o

-

: Led will blink (white color).

During call door panel, guard or intercom process

telephone in communication: Led switch on (white color).

-

: Led switch on (red color).

"Do not disturb" mode

"Default tones

& tones volume

": Led blink 9 times (red color).

-

Led switch on (red color).

"Doctor mode":

HZ: (

)

Black

Funtion status LED:

Descrip

terminals:

tion connection

During the call or communication processes: one press

will activate the lock release 2. In standby (handset on
the hook)

: press the button for 3 sec. to activate the

staircase light the

2+

&

modules

(

SAR-G

SAR-12/24

required

5 short press to default tones & tones

).

volume (led

blink 9 times). In standby (handset off

the hook): 2 short press to “intercom” call (within the
same apartment) and press for 3 seconds to
“autoswitch-on” function. See pages 16-17.

In standby

: short press, it

(handset on the hook)

allows to change tone call volume, on every short
press telephone reproduces the selected volume
(cyclic min/ med/ max/ off

"do not disturb").

In communication: on every short press, it allows
to change the speaker of the T-ART audio volume
(cyclic 4 audio levels). See p. 16-17.

HZ: ( ed)

R

GND:

(Black)

SA:

( ed)

R

During the call or communication processes: one

press will activate the lock release . In standby

1

(handset on or o

ff

the hook)

: press the button for 5

seconds to activate/deactivate the "Doctor mode"
function. See page 16-17.

BUS, BUS: Communication BUS (non-polarised).

SA, GND: Auxiliary call repeater output.

SAV-12". M

dc

( ax 50mA/12V

).

HZ, HZ: Apartment front door button input:

Connect only on the master

. The signal received is then transmitted

telephone

to the slave telephones in the same apartment through the BUS.

Note: HZ push button function mode:

When HZ push button is pressed will be call tone and activate the output of

auxiliary call repeater with standby telephone, call process, communication process (HZ tone with lower audio
level), intercom process and "Do not disturb" mode.

BUS

BUS

a.

b.

c.

d.

Handset.
Function push buttons.
Raised dots for the visually impaired people.

In call

m

tion:

/ com unica

Above these raised dots is the "Door opening"

button.

Status Leds.

Wall mounting connector fixing (x4).
Gol ar use.

m

Configuration switches.
Bus connection terminals.
Label.
Apartment front door button input

.

"HZ"

Auxiliary call repeater output SAV-12.

.

dc

(máx 50mA/12V

).

e.

f.

g.
h.

i.
j.

k.

b

a

d

e

i

k

h

g

f

c

AUX

DIP  8,9

00 - Master
10 - Slave 1

OFF = 0 | ON = 1

01 - Slave 2

11 - Slave 3

DIP  1 to 7

Monitor address

DIP  10

End of line resistor

BUS

HZ

GND

GOLMAR S.A.

C/ Silici, 13. 08940-SPAIN

SA

e

j

No function.

SOUL

ART

S 110

4

1 G2+ / T-ART G2+ AUDIO DOOR ENTRY SYSTEM KIT

Summary of Contents for KIT SOUL S4110 ART 1 G2+/T-ART G2+

Page 1: ...Cód 50123042 TS4110 AUDIO EN REV 0321 G2 2 wire installation INSTRUCTIONS MANUAL Kit Soul Art 1 Terminal T Art Telephone TECHNOLOGY J Brown ...

Page 2: ... Art 1 G2 Terminal Cross sections and distances 0 2 One apartment with one access panel and one terminal 20 One apartment with two access panels terminal 0 and one 2 One apartment with up to two access cascad and up to four terminals in e 1 2 One apartment with up to two access and up to four terminals connection in 1 2 electrical junction box T Art G2 telephone Cross sections and distances 2 2 On...

Page 3: ...ry output of the door panel press the button A single press activates the lock release or auxiliary output for 3 seconds an audible tone be indicated on the door panel Detailed operation of the terminal is described on pp 8 to 11 SYSTEM OPERATION T ART TELEPHONE To make a call the visitor needs to press the button for the apartment an audible two tones indicates that the call is being made At this...

Page 4: ... cover without first disconnecting the power supply Replace it once all connections have been made Connect the wires to the installation terminals following the instructions in the diagrams C A Terminal telephone Bus connection terminals B Door panel Bus connection terminals C Protective cover for the current input D Current input connection terminals E Detail of the current input terminals withou...

Page 5: ...one hole F Front fixing screw G Illumination module H Wall fixing hole x3 Do not overtighten the fixing screws I Illumination module gasket J Installation terminals K Cable grommet L Illumination module connector M Configuration switches N Volume control potentiometer H H F D C E J SOUL ART S 110 4 1 G2 T ART G2 AUDIO DOOR ENTRY SYSTEM KIT ...

Page 6: ...he screws supplied 5 Connect the cables to the terminals following the instructions in the installation diagrams Before replacing the and closing the door panel perform the necessary settings illumination module address door panel illumination module audio level setting etc as indicated throughout this manual Make sure that the gasket is properly fitted Installation terminals J BUS BUS CV CV AP C ...

Page 7: ...UL 1A PANEL Switch 1 Defines the door panel address Switch 2 must be OFF OFF OFF OFF OFF O OFF N Door panel 1 Door panel 2 Apartment 1 Switches and must be OFF 3 4 Setting the audio level If the audio volume on the door panel after starting up the device is not adequate use the volume control potentiometer This setting affects the communication and confirmation tone audio level N ON 1 2 3 4 ON 1 2...

Page 8: ...ls See page 10 11 Led will blink white color During call door panel guard or intercom process Terminal in communication Led switch on white color Led switch on red color Do not disturb mode Default tones tones volume Led blink 5 times red color Led switch on red color Doctor mode HZ Black Funtion push button status LED Descrip terminals tion connection During the call or communication processes on...

Page 9: ...minal Switch 8 to ON Switch 8 to OFF Apartment 1 1 2 3 ON 4 5 6 7 8 9 10 1 2 3 ON 4 5 6 7 8 9 10 1 2 3 ON 4 5 6 7 8 9 10 1 2 3 ON 4 5 6 7 8 9 10 1 2 3 ON 4 5 6 7 8 9 10 Master Slave 1 Slave 2 Slave 3 Switch 10 Configures the end of line In installations with terminals only it must always be in the OFF position 1 2 3 ON 4 5 6 7 8 9 10 1 2 3 ON 4 5 6 7 8 9 10 Configuration switches ART 1 G2 TERMINAL...

Page 10: ... will turn on red indicating that the do not disturb mode is active The terminal will not sound the ring tone when a call is received see note HZ on page 8 To deactivate the do not disturb mode press the button each short press reproduces the selected volume minimum medium maximum and no volume do not disturb mode stop pressing once the volume minimum medium or maximum of the desired call tone has...

Page 11: ...e button Each short press on the button reproduces a different call tone stop pressing once you have selected the desired door panel call tone on the terminal To exit and save the selected call tone in the terminal press the button for 3 seconds until you hear 2 confirmation tones indicating that the terminal has saved and left the configuration mode Make a call to check that the terminal has been...

Page 12: ...minal Fixing the terminal s wall mounting connector to the wall Positioning the terminal Avoid dusty or smoky environments or locations near sources of heat Connect the cables to the terminal see p position the terminal in front of the wall mounting connector ensuring that 8 the holes in the base of the terminal line up with those on the connector and then move the terminal downwards until the ter...

Page 13: ...ith the screws supplied Positioning the embedding box and fitting the wall mounting connector Positioning the terminal Avoid dusty or smoky environments or locations near sources of heat Connect the cables to the terminal see p position the terminal in front of the wall mounting connector ensuring 8 that the holes in the base of the terminal line up with those on the connector and then move the te...

Page 14: ...unication processes one press will activate the lock release In standby 1 handset on or off the hook press the button for 5 seconds to activate deactivate the Doctor mode function See page 16 17 BUS BUS Communication BUS non polarised SA GND Auxiliary call repeater output SAV 12 M dc ax 50mA 12V HZ HZ Apartment front door button input Connect only on the master The signal received is then transmit...

Page 15: ...ne master The terminal only terminal Switch 8 to ON Switch 8 to OFF Apartment 1 1 2 3 ON 4 5 6 7 8 9 10 1 2 3 ON 4 5 6 7 8 9 10 1 2 3 ON 4 5 6 7 8 9 10 1 2 3 ON 4 5 6 7 8 9 10 1 2 3 ON 4 5 6 7 8 9 10 Master Slave 1 Slave 2 Slave 3 Switch 10 Configures the end of line In installations with terminals only it must always be in the OFF position 1 2 3 ON 4 5 6 7 8 9 10 1 2 3 ON 4 5 6 7 8 9 10 Configura...

Page 16: ...de is active The telephone will not sound the ring tone when a call is received see note HZ on page14 To deactivate the do not disturb mode press the button each short press reproduces the selected volume minimum medium maximum and no volume do not disturb mode stop pressing once the volume minimum medium or maximum of the desired call tone has been selected the function LED will turn off indicati...

Page 17: ...oduces a different call tone stop pressing once you have selected the desired door panel call tone on the telephone To exit and save the selected call tone in the telephone press the button for 3 seconds until you hear 2 confirmation tones indicating that the telephone has saved and left the configuration mode Make a call to check that the telephone has been configured with the desired call tones ...

Page 18: ...nector to the wall Positioning the telephone Avoid dusty or smoky environments or locations near sources of heat Connect the cables to the telephone see p 4 position the telephone in front of the wall mounting connector ensuring 1 that the holes in the base of the telephone line up with those on the connector and then move the telephone downwards until the telephone is securely fixed to the connec...

Page 19: ...x with the screws supplied Positioning the embedding box and fitting the wall mounting connector Positioning the telephone Avoid dusty or smoky environments or locations near sources of heat Connect the cables to the telephone see p 4 position the telephone in front of the wall mounting connector 1 ensuring that the holes in the base of the telephone line up with those on the connector and then mo...

Page 20: ...m number of in cascade is 4 terminals Maximum two access door panels A Distance between power supply and the farthest door panel B Distance between power supply and the farthest terminal Use two twisted pairs for each bus line Important Never use UTPcable of copper clad aluminum CCA DOOR PANEL 2 SOUL 1A DOOR PANEL 1 1A SOUL DOOR PANEL 1 SOUL 1A ART G2 1 FA G2 LITE L N Mains 100 240Vac FA G2 LITE N...

Page 21: ... LITE Not 9 e see page To terminal factory setting define whether the is master or slave Not 9 e see page To terminal factory setting define whether the is master or slave APARTMENT 1 MASTER TERMINAL ART G2 1 BUS AUX APARTMENT 1 SLAVE 1 TERMINAL ART G2 1 BUS AUX APARTMENT 1 SLAVE 3 TERMINAL ART G2 1 BUS AUX APARTMENT 1 MASTER TERMINAL ART G2 1 AUX APARTMENT 1 SLAVE 1 TERMINAL ART G2 1 AUX APARTMEN...

Page 22: ...240Vac Note Telephone set to master factory setting see page 15 Note Telephone set to master factory setting see page 15 WIRING DIAGRAMS Cross sections and distances Type of cable A B 2 x 0 75mm 18 AWG 30 m 30 m 60 m 60 m 80 m 190 m CAT5 RAP GTWIN HF Maximum 1 apartment The maximum number of s in the apartment is 4 telephone The maximum number of in cascade is 4 telephones Maximum two access door ...

Page 23: ... see page 15 To telephone factory setting define whether the is master or slave T ART G2 T ART G2 T ART G2 T ART G2 Make the connections in electrical junction box BUS BUS BUS BUS T ART G2 BUS AUX T ART G2 BUS AUX T ART G2 BUS AUX AUX AUX AUX AUX APARTMENT 1 MASTER TELEPHONE APARTMENT 1 SLAVE 1 TELEPHONE APARTMENT 1 SLAVE 2 TELEPHONE APARTMENT 1 SLAVE 3 TELEPHONE APARTMENT 1 MASTER TELEPHONE APART...

Page 24: ...e is second with the possibility of setting it to between 0 5 and 10 seconds 1 installer programmable If the lock release to be used is alternating current use a relay and transformer suitable for the consumption as well as the varistor supplied The example shows a Golmar SAR 12 24 relay and a TF 104 transformer 12Vac 1 5A CV BUS CV BUS IN IN C NC NA PRI PRI Mains 100 240Vac SEC SEC SOUL 1A DOOR P...

Page 25: ...al received is then transmitted to the slave telephones in the same apartment CV BUS CV BUS C NA AP T ART G2 IMPORTANT Installation with 2 access door panels and AP button on both door panels one of the door panels must connect the AC lock release instead of DC lock release with a SAR 12 24 relay and a transformer TF 104 see page 4 2 HZ HZ AP AP Connection for an apartment door button ART 1 G2 ter...

Page 26: ... moisture with a soft dry cloth that sheds no fibres terminal telephone CLEANING THE DOOR PANEL Do not use solvents detergents or cleaning products that contain acids vinegar or abrasive components Use a soft damp cloth not wet that sheds no fibres Always wipe the door panel in the same direction from top to bottom After cleaning the door panel remove any moisture with a soft dry cloth that sheds ...

Page 27: ...27 NOT S E SOUL ART S 110 4 1 G2 T ART G2 AUDIO DOOR ENTRY SYSTEM KIT ...

Page 28: ...This product meets the essentials requirements of applicable European Directives regarding Electrical Safety Electromagnetic Compatibility 20 5 ECC 14 3 1 30 and 20 4 ECC NOTA El funcionamiento de este equipo está sujeto a las siguientes condiciones 1 Este dispositivo no puede provocar interferencias dañinas y 2 debe aceptar cualquier interferencia recibida incluyendo las que pueden provocar un fu...

Reviews: