6
Installation
The door panel has been designed to withstand diverse environmental conditions. It is however advisable to take
extra precautions to prolong its service life, such as locating it in a covered area.
For correct installation: (locate the top of the door panel at a height of 1.65m).
1. Remove the metal front piece of the door panel by loosening the bottom screw with the Allen key supplied. On
the back of the front piece, you will find the button personalisation label.
2. Remove the screws that secure the
.
Illumination module
3. Present the door panel to the wall, positioning the top at 1.65m. Pass the installation cables through the cable
grommet.
4
H
. Drill three 6mm holes at the indicated points ( ), see p. 5. Insert the plugs supplied and fix the door panel to the
wall using the screws supplied.
5. Connect the cables to the terminals following the instructions in the installation diagrams.
Before replacing the
and closing the door panel, perform the necessary settings (
illumination module
address door
panel
illumination module
, audio level setting, etc.), as indicated throughout this manual. Make sure that the
gasket is properly fitted.
Installation terminals ( )
J
BUS
BUS
CV-
CV+
AP+
C
NA
AP-
ON
1
2
3
4
BUS BUS
,
: communications bus (non-polarised).
CV CV
-,
+: lock release output 12Vdc (maximum 270mA).
AP
AP
+,
-: remote activation button connection.
Note: For correct
operation, the
’s address 1 must be connected to
terminal
the Bus.
IMPORTANT:
Installation with 2 access door panels and
AP button on both door panels, one of the door panels
must connect the AC lock release (instead of DC lock
release). SAR-12/24
required,
relay
a TF-104 transformer
&
see pages 24 to 25.
C,
: potential-free relay output (maximum 6A/24V).
NA
SOUL/1A PANEL
SOUL
ART
S 110
4
1 G2+ / T-ART G2+ AUDIO DOOR ENTRY SYSTEM KIT