background image

 
 

                                                                           

 
                                    

 

GAS GRIDDLE & COMBINATION GRILL AND             
              SALAMANDER TOASTER 

 

 

 

        

 

                              PROUDLY AUSTRALIAN MADE 

 

         INSTALLATION PROCEDURE – USER MANUAL 
                           SERVICE INSTRUCTION 

             MODELS GPG-30, GPG-45, GPGDB-12,24,36,48,                        
                                   GPGDB/SA-24,36 
                           

       

 

                                                        

               

GAS APPROVAL NO. 6006 & 6215

   

              

 

 

 

       

 

 

                                                                   ESTABLISHED 1911 

                            The Cooking Equipment Professionals 

                                       www.goldsteineswood.com.au

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for GPG-30

Page 1: ...TOASTER PROUDLY AUSTRALIAN MADE INSTALLATION PROCEDURE USER MANUAL SERVICE INSTRUCTION MODELS GPG 30 GPG 45 GPGDB 12 24 36 48 GPGDB SA 24 36 GAS APPROVAL NO 6006 6215 ESTABLISHED 1911 The Cooking Equipment Professionals www goldsteineswood com au ...

Page 2: ...S Page 6 7 5 LIGHTING INSTRUCTIONS Page 8 6 TECHNICAL INSTRUCTIONS Page 9 7 TECHNICAL DATA Page 10 11 8 CLEANING INSTRUCTIONS Page 12 9 PROBLEM SOLVING Page 13 14 15 10 DRAWINGS SPARE PARTS GPG 30 45 Page 16 17 11 DRAWINGS SPARE PARTS GPGDB SA 24 36Page 18 19 12 WARRANTY Page 20 13 BRANCHES Page 21 IM027B2 p2 ...

Page 3: ... designed to give long and satisfactory service and incorporate the best possible materials and workmanship Proper installation adjustment and preventative maintenance are vitally important if efficiency and appearance are to be maintained Read these instructions carefully as they contain important safety information regarding the installation use and maintenance of the appliance RECEIVING INSPECT...

Page 4: ...MIN 25mm REAR WALL CLEARANCE FROM COMBUSTIBLE MATERIALS AND THAT THE UNIT IS PLACED ON A FIRE PROOF BASE and adjust feet using a spirit level checking from back to front and side to side 2 Have a licensed gas fitter or our local gas company connect the appliance to the mains pressure supply The gas inlet connection can be seen in the appendix The appliance must be installed in accordance with rule...

Page 5: ...ctly for satisfactory operation the matter should be referred to the manufacturer or the local gas supply authority Ensure that the pressure at the pressure test point on the manifold is as per the rating plate or as per page of this manual If the pressure is not the same use a screwdriver to adjust the pressure regulator turning screw clockwise will increase the pressure Turn the control knob to ...

Page 6: ...and burner and the side of the unit Tilting fret slightly slide fret onto rails above burners ensuring that the fret has the points facing down refer Fig 1 Step 4Using your right and your left hand in conjunction slide the fret to the right hand side The first fret that you put into each row should be the right hand fret which will be positioned above the space between the 2 far right burners The ...

Page 7: ... C D D TURN TO MINIMUM FLOW MIN GAS FLOW TO MAINTAIN FLAME Adjustable to suit type of gas used as precise and accurate TO OPERATE Push in and turn knob to position B light pilot burner and hold in for 10 seconds to establish Pilot flame release pilot burner should remain alight and turn to position C for full flow of gas for minimum gas flow turn to position D Adjustable to suit type of gas used F...

Page 8: ...tween L P and N G If appliance cannot be correctly adjusted advise the local gas authority or the appliance manufacturer Sit 3 way pilots are used on the GPGDSA 24 36 The needle needs to be changed for conversion between N G and L P G To adjust pilot flame size remove the screw cover on the back of the pilot then adjust the screw to set the desired flame size turning screw clockwise will decrease ...

Page 9: ...toward the rear until the air shutter which is attached to the throat of the burner clears the injector Allow the front of the burner to drop down and whilst still holding the back of the burner up pull towards the front CONTROLS The only controls are the PEL 21S gas valves All are accessible after the front stainless steel fascia is removed refer to attached pages for instructions on using gas co...

Page 10: ...RSION INSTRUCTIONS To convert from N G to L P gas do the following 1 Replace N G burner injectors with L P injectors refer to table on following page 2 Replace pilot injectors to required size N G 32 L P 22 3 Disconnect regulator from gas supply line reconnect LP Regulator 4 Reset pressure test point on manifold to 2 60 kPa 5 Adjust burner aeration slide IM027B2 p10 ...

Page 11: ...40mm x 200mm GPG 45 Air Inlet 1100mm x 25mm Flue gas outlet 1100mm x 25mm Flue gas outlet 1100mm x 25mm MODEL WIDTH MM DEPTH MM HEIGHT MM GPG 30 745 690 445 GPG 45 1130 690 445 SIDE VIEW GPG 45 or AGPG S 45 690 FRONT VIEW GPG 30 GPG MODELS GPG 45 or AGPG S 45 1120 GPG 30 740 690 55 1015 915 685 IM027B2 p11 ...

Page 12: ...t the grease can regularly while cleaning griddle otherwise grease can will overflow Let griddle plate run on high for a few minutes to completely dry the water from the plate Using a basting brush after plate is completely dry and cool cover the plate with a thin layer of cooking oil to maintain the shinny appearance of the plate When cleaning the stainless steel surface under NO circumstances sh...

Page 13: ...ctor orifice for correct size also check governor pressure b Cause Remedy Under active flue or flue restriction Check for obstruction in flue way 3 Uneven cooking characteristics from side to side a Cause Remedy If single burner construction oven Locate burner on level flame burner out of alignment b Cause Remedy Appliance not level side to side Level appliance with spirit level c Cause Remedy Bur...

Page 14: ...essure Fit or adjust governor b Cause Remedy Contamination of pilot orifice Clean pilot orifice c Cause Remedy Extreme over gassing of main Check burner jet orifice size or Burner Governor adjustment d Cause Remedy Defective thermocouple Replace e Cause Remedy Defective safety shut off valve Replace f Cause Remedy Poor connection between thermocouple Refer to servicing instructions and lead and va...

Page 15: ...ack a Cause Remedy Excessive aeration Adjust 9 Yellow Flame a Cause Remedy Too much gas to burner Check gas pressure and burner Jet orifice b Cause Remedy Insufficient aeration Adjust 10 Harsh noisy flame a Cause Remedy Excessive aeration Adjust IM027B2 p15 ...

Page 16: ...10 DRAWING MODEL GPG 30 GPG 45 IM027B2 p16 5 1 11 2 14 10 9 13 4 2 1 12 7 8 6 3 ...

Page 17: ...30 INJECTOR 1 30mm L P 5 GIJ00022 PILOT SPUD FOR L P G 5 GIJ00032 PILOT SPUD FOR N G 6 GPIC0002 ELECTRODE CERAMIC GPIB0002 509F 7 GPIB0002 BODY PILOT POLIDO PF PFC OVEN PFG CHD 8 GTC00320 THERMOCOUPLE L 320mm 9 ESPL0402 LEAD H T 400mm FOR SPARKER GRIDDLE 10 GBNGPG00 BURNER GPG30 GPG45 11 PF 00P33 AIR INLET CONTROL 12 PFG00A02 GREASE ASSEMBLY 13 MLESSBF1 FEET S S BULLET D 41mm 1 5 8 14 GMA00002 MAG...

Page 18: ...11 DRAWINGS MODEL GPGDB SA 24 36 2 8 9 1 4 7 2 1 1 1 1 1 6 5 6 2 9 1 1 9 5 1 1 6 3 1 ...

Page 19: ...A24 8 GGS24P08 DRIP TRAY 9 MKNPLM21 KNOB GASCOCK GCKPF001 GCKGR001 PF BOIL 10 GCKGR001 GASCOCK RBA GPG PF WITH F F DEVICE 11 MLESSBF1 FEET S S BULLET D 41mm 1 5 8 12 MLEPLBF1 FEET PLASTIC BULLET 2D 13 ESP00003 SPARKER PIEZO C W SPRING WASHER NUT 14 ESPL0402 LEAD H T 400mm FOR SPARKER GRIDDLE 15 GTC00320 THERMOCOUPLE L 320 TOP BURNER 16 GPI00003 PILOT RBA GPGDSA 3 WAY 17 GPIC0003 ELECTRODE CERAMIC ...

Page 20: ...ip in accordance with the warranty offered This undertaking covers the provision of labour and parts for 12 months from the date of delivery to the purchaser This undertaking applies only to state capitals Remote areas are not covered by this commitment and special enquiries should be made Note Travel time not covered by warranty To the maximum extent permitted by law any liability on Goldstein Es...

Page 21: ...3 Unit 3 260 264 Wickham Road 49 Logan Road Moorabbin Woolloongabba Victoria 3189 Queensland 4102 Phone 03 9553 1488 Phone 07 3891 1466 Fax 03 9553 0785 Fax 07 3393 1333 South Australia Western Australia Suite 26 10 Wittenberg Drive 283 287 Sir Donald Bradman Drive Canning Vale South Australia 5032 Western Australia 6155 Phone 08 8238 3423 Phone 08 9456 0559 Fax 08 8238 3400 Fax 08 9456 0554 IM027...