7-19
(2) CHECKOUT PROCEDURES FOR RELAY.
- PROBLEM (A) -
Vent fan motor and oven lamp turn on without touching
START key when the door is closed.
Remove the mate connector of I/O
CON from the circuit board.
Does the unit still operate?
Replace the
circuit board
Replace
RELAY1, 12
NO
NO
YES
YES
GOOD
Defective
RELAY1, 12
- PROBLEM (B) -
Vent fan motor and oven lamp turn on When the door
is closed and START key is touched.
Measure the voltage at pin NO.
47, 50 of U01 or 48, 49, 51 of U01
Voltage reading: 0 Vdc
Replace the
circuit board
Defective
RELAY1, 12 or poor
connection of
RELAY1, 12
Replace
RELAY1, 12 or correct
the connection.
YES
NO
NO
YES
GOOD