POWER 

On the back panel of the Goldmund Mimesis 27.5 preamplifier the switch is used to power 
on the preamplifier. In regular use, this switch is left ON and the circuits of the preamplifier 
are left ON. The standby function of the remote control is only shorting the output to ground 
for safe removal of the cables to the power amplifier.  
 
The preamp can be powered off by switching the switch to the OFF position. A special 
safety circuit switches the preamp to muting, to avoid any disturbance to reach the power 
amplifier and the speakers, even if the preamplifier is disconnected from the AC plug by 
accident. 
However, to optimize the sound quality of the preamplifier and insure the best reliability, 
Goldmund recommends that the unit is left powered ON. 

 

MUTING 

Muting is controlled from the remote control. It can be used to temporarily turn the volume 
down without touching the volume control. When returned to normal, the level of the 
preamplifier is returned to where it was when the muting was activated.  
 

VOLUME 

May be adjusted manually by turning the volume control or on the remote by  or 
-. 

 
SELECTOR 

Selects one of the available input for listening (8 if D/A option is enabled, 5 if not), including 
the one tape inputs for monitoring. A step clockwise is selecting the next input; a step 
counterclockwise selects the previous input. A display on the front panel shows the number 
of the input selected. Selection may be also made on the remote by pressing the key 
corresponding to the input on the Analog section of the remote.  

 

RECORD 

Record is factory set. Tape in is always input 5. If input 5 is selected, tape out is 
disconnected. Otherwise, tape out is connected to the selected input. E.g. input 3 is 
selected, so tape out receive signal from input 3. 
 

 

Summary of Contents for MIMESIS 27.5

Page 1: ...USER MANUAL GOLDMUND MIMESIS 27 5 Analog Preamplifier...

Page 2: ...production of sound and image At Goldmund we strive to lead in the creation development and manufacture of the industry s most advanced technologies including audio and video systems home networking a...

Page 3: ...OLDMUND MIMESIS 27 5 Analog Preamplifier 3 Table of Contents 1 SETTING UP THE MIMESIS 27 5 5 2 FIRST INSTALLATION CONNECTIONS 7 4 SOUND QUALITY OPTIMIZATION 9 5 CLEANING 9 6 TECHNICAL SPECIFICATIONS 1...

Page 4: ...h bandwidth and computer linking which are becoming necessary for an accurate transcription of today s best analog messages in complete systems with video computer and audio associated components Only...

Page 5: ...on digital signals The connections between the analogue sources and the preamplifier are also critical Ultra low reflection cables are absolutely mandatory Goldmund recommends using the special Goldmu...

Page 6: ...ovided on the back plate of the preamplifier Adjust it with a screwdriver if the line voltage provided is not appropriate ATTENTION On the 220V position the Goldmund Mimesis 27 5 preamplifier will fun...

Page 7: ...vided with this option to connect the Mimesis 27 5 to a computer serial output and follow the instructions delivered with the software This connector has to be left open in all the other situations 2...

Page 8: ...left powered ON MUTING Muting is controlled from the remote control It can be used to temporarily turn the volume down without touching the volume control When returned to normal the level of the prea...

Page 9: ...or a few days the optimum sound quality is only reached after many hours This is why Goldmund recommends leaving the MIMESIS 27 5 powered on 5 CLEANING The Goldmund Mimesis 27 5 preamplifier usually r...

Page 10: ...to 3 6 V RMS 0 1 dB 0 50 kHz 1 dB 0 150 kHz 3 dB 0 300 kHz INPUT SENSITIVITY Nominal level 2 25 V RMS Saturation level 3 6V RMS Nominal input impedance 50 kOhms GROUP DELAY Propagation delay 1 ms stab...

Page 11: ...sius Internal temperature 45 to 65 degrees Celsius POWER SUPPLY Nominal line voltage 117 or 234 V Input voltage range 10 Maximum power consumption 70 W GROUNDING Separated ground and earth signal Chas...

Page 12: ...lugs Mains fuse 500mA slow blow Voltage selector 110 220 V Earthing post yellow green Input connectors RCA right and left for Tape and line inputs Doubled Output connector RCA right and left Output c...

Reviews: