Access to By Pass Screw
-
Light the burner and turn to minimum setting (marked small flame).
The flame should
minimum setting and should not extinguish when passing from maximum setting to low
setting.
-
If adjustment is necessary, remove the control knob by pulling upward. The bypass screw
is accessible
via the control knob
Turn
the bypass screw anti
-
clockwise to increase the turn
-
down rate
Access to manifold, gas taps and burner assembly
-
Remove glass hob and control knobs.
-
To remove gas cocks. Unscrew the locking nut (between cock and burner). Remove
screws, the cock can now be removed from the manifold.
If access to the barrel is required, remove two screws, which retain spindle to body. If lu-
bricating the mechanism use Regosine Moly LM or other approved grease.
To replace electrode
-
Remove screw from the clamp holding the electrode and thermocouple and note
the
adjustment setting height of each. Replace electrode and then fit clamp and screw.
SERVICING INSTRUCTIONS
WARNING! DANGER 240
VOLTS 50Hz
DISCONNET POWER BEFORE SERVICING UNIT DO NOT