Page 11
ADJUSTING THE BURNER MINIMUM FLAME HEIGHT :
NOTE
:
This adjustment can only be performed by authorised service per-
sonnel
. The minimum burner flame is factory adjusted for the gas type stated on the gas type label
adjacent to the gas connection
and should not require adjustment
.
Adjustment may be require
d
if the hotplate has been converted from Natural gas to Uni-
After connecting to gas
,
check for leaks using soapy solution
,
never a naked flame
.
Fit the duplicate data plate
(
supplied in separate bag
)
on a surface adjacent to the hotplate
,
for example
,
the inside of the cupboard door so it is clearly visible for any service technician
.
SETTING THE GAS PRESSURE :
Fit a manometer with a 6 mm rubber hose to the test point on the regulator
(
for natural gas
)
.
For all the mod-
els
,
light all burners on and adjust test point pressure to 1
.
00 kPa
.
Turn burner
s off and on again and recheck the pressure is same as set previ-
ously or adjust as required. TEST FOR CORRECT OPERATION :
After installation and test point setting
,
each burner ignition and operation must
be teste
d
individually and with all burners operating
.
This testing must be done by the installer befor
e leaving.