Goldline N12- manual-ULPG Jan 2012
7
SERVICING INSTRUCTIONS
MINOR ADJUSTMENT
Access to By Pass Screw
- Light the burner and turn to
minimum setting (marked small
flame).
- The flame should be stable on
minimum setting and should not
extinguish when passing from
maximum setting to low setting.
- If adjustment is necessary, remove
the control knob by pulling upward.
The bypass screw is accessible
via the control knob spindle. Turn
the bypass screw anti-clockwise to
increase the turn-down rate
Access to manifold, gas taps and burner
assembly
- Remove glass hob and control knobs.
- To remove gas cocks. Unscrew the locking nut
(between cock and burner). Remove screws, the
cock can now be removed from the manifold.
If access to the barrel is required, remove two
screws, which retain spindle to body. If lubricating
the mechanism use Regosine Moly LM or other
approved grease.
To replace electrode
- Remove screw from the clamp holding the
electrode and thermocouple and note the
adjustment setting height of each. Replace electrode
and then fit clamp and screw.
FAULT ISOLATION CHART
FAULT
CAUSES
REMEDY
Burner will not light
1. Air in gas line
2. Blockage in line
3. Ignition not sparking
4. Flame failure device faulty
5. Check the battery
(applicable to DC version)
1. Purge gas line
2. Trace back and clear
3. Check lead and electrode
4. Replace thermocouple and test
5. Replace the battery
Burner lights back to
injector
1. Excessive lint up burner
mixing tube
2. Excessive gas pressure
1. Remove and clean burner
2. Check gas regulator pressure.
Adjust if necessary.
Burner has explosive
ignition
1. Excessive gas pressure
1. Check gas regulator pressure.
Adjust if necessary.
Ignitor not sparking
1. Electrode gap
2. Ignition connection
1. Check gap, adjust if not
between 4-5mm
2. Check connection to ignitor,
replace if faulty.
If any problem cannot be rectified please contact the agent in your state or the gas supply authority service department
or contact the product manufacturer.
WARNING!
DANGER 220 VOLTS 50Hz.
DISCONNET POWER BEFORE SERVICING UNIT
DO NOT MODIFY THIS APPLIANCE