Goldline N12- manual-ULPG Jan 2012
5
- Please ensure that the flexible hose shall not kink, in permanent deformation
position, exposed to exceeding heat (more than what is certified) or subject to
abrasion.
- Please ensure the hose assembly is restrained from accidental contact with the flue
outlet of an under bench oven.
- To inspect and replace the hose regularly.
- The length of the flexible hose must be kept to a minimum.
8. Use a spanner at the flat area provided to hold the regulator firmly, when making
the join. Refer diagram below.
Pressure test point:
- This is provided in the gas regulator.
- Remove the screw; connect the hose from the pressure gauge.
- Turn on the gas to the large burner and manually light the burner.
- The pressure is shown on the data plate.
- To increase the pressure, loosen locking nut and turn clockwise.
- Disconnect gauge and replace test point screw.
10. Test the appliance:
- Depress each control knob and turn to full flame setting.
- The burner will ignite. Adjust control knob to desired setting. Normally, no adjustment
should be necessary.
Note:
The cook top must be installed with provision to allow the gas to be turned off and
disconnected for servicing and removal of the appliance as required from gas supply.
WARNING!
HOSE ASSEMBLY MUST BE RESTRAINED TO PREVENT ACCIDENTAL
CONTACT WITH THE FLUE OF AN UNDERBENCH OVEN.
9. Once they are tightened
securely, turn the gas on and
check for leaks using a soap
solution and brush around all
joints and connections.
Pressure test point for LP and ULP gas only.
Use the regulator provided for town and natural gas.