5. Click “

I Agree

” button to continue.

 

 

 

6. Click “

Install

” button to continue.

 

     

 

 

Summary of Contents for Xpeed LAN 500

Page 1: ...User s Manual...

Page 2: ...its serviceable life this product should not be treated as household or general waste It should be handed over to the applicable collection point for the recycling of electrical and electronics equip...

Page 3: ...2 2 1 Installing Powerline Device 2 2 2 Installation of Powerline Utility 3 2 3 Uninstallation of Configuration Utility 10 Chapter 3 Configuration Utility Setup 11 3 1 Map View 11 3 2 Detailed View 1...

Page 4: ...MHz 68 MHz Security 128 bits AES encryption IEEE802 3 10Base T IEEE802 3U 100Base TX 1 3 LED Indicators The Powerline Ethernet Adaptor has three LEDs indicator Turn on when connected to AC power supp...

Page 5: ...ed RJ45 Ethernet cable from your xDSL Cable Modem s Ethernet port to the Xpeed LAN 500 s LAN Ports 2 Connect the Xpeed LAN 500 to your wall mounted power outlet 3 Check if the PLC LED of Xpeed LAN 500...

Page 6: ...is document are generated from Windows XP screen shots for Windows 7 Vista and Windows 8 will be similar 1 In order to install insert Configuration Utility CD ROM into the computer s CD ROM drive The...

Page 7: ...4 Xpeed LAN 500 3 Please click Power line Utility button to continue 4 Click Next button to continue...

Page 8: ...5 Xpeed LAN 500 5 Click I Agree button to continue 6 Click Install button to continue...

Page 9: ...6 Xpeed LAN 500 7 Click Finish button to continue 8 Click Next button to continue...

Page 10: ...7 Xpeed LAN 500 9 Click I Agree and then click Next button to continue 10 Click Next button to continue...

Page 11: ...8 Xpeed LAN 500 11 Click Next button to continue 12 Click Close button to exit...

Page 12: ...click the utility icon on desktop 14 You can see your device working well The top panel of the screen shot shows a Homeplug device connected locally to your computer The bottom panel shows one device...

Page 13: ...uninstall the Configuration Utility go to the Control Panel of your system 2 Open the Add Remove Programs 3 Select and double click on the Powerline Utility in the Add Remove Programs Properties 4 Fol...

Page 14: ...orks The Utility will use a Graphical User Interface GUI with limited user selectable options 3 1 Map View In order to start the utility double click the utility icon on desktop Figure 3 1 shows the m...

Page 15: ...can select the local device by clicking on it and then click the Connect button to its right The status area above RESET NET ID button indicates that your PC is connected to that same device Once con...

Page 16: ...ices associated with the currently selected local device are displayed Also along with the remote device MAC the signal strength device DAK if available and device alias name if available is displayed...

Page 17: ...ton A dialog box will appear as shown in Figure 3 3 to type the password The selected device name is shown above the password field and the password can be verified by hitting the OK button The Passwo...

Page 18: ...allows the user to enter both a device name and the password If a device was not found the user will be notified and suggestions to resolve common problems will be presented Figure 3 4 Add Remote Devi...

Page 19: ...N 500 The Scan button is used to perform an immediate search of the HomePlug devices connected to the Powerline network By default the utility automatically scans every few seconds and updates the dis...

Page 20: ...tion and also should maintain the history of remote devices This information can be saved or printed The following is the list of information required to be stored for a remote device Device alias nam...

Page 21: ...n will set the network name with the value in the text box in the local device 2 Set Remote Device s This button will set the network name with the value in the text box in the local device as well th...

Page 22: ...are To upgrade the firmware in a device click the upgrade button Use the browse buttons to select the firmware and PIB files NOTE The utility only supports upgrading of the local device Remote device...

Page 23: ...500 3 5 Options This view is used to configure PPU settings For now scan options is the only thing present in which auto scan can be checked and scan interval can be set minimum 2 seconds and maximum...

Page 24: ...3 7 Enabling Trace Power Packet utility allows end user to enable disable Log levels to control the logging Logging can be controlled by modifying PPUOptions ini file present in installation folder Wh...

Page 25: ...omePlug AV powerline communication devices can form multiple logical networks over a common powerline or coax medium There are many situations when it is desirable to add new devices to or remove old...

Page 26: ...ET ID button on the second device for less than 3 seconds RESET NET ID button on the second device must be pressed within 1 minute by default however the interval is programmable 4 Wait for connection...

Page 27: ...LED on the adder will flash unevenly until the RESET NET ID button on the adder is pressed again or the joiner is reset by pressing the RESET NET ID button for 5 8 seconds as described in Case 3 The j...

Page 28: ...ET ID button on the leaver for 5 8 seconds The device will reset and restart with a random NMK 2 Wait for reset to complete and the PLC LED will be OFF The PWR LED on the leaver will momentarily extin...

Page 29: ...f operation in which an adder device in the network remains in the adder state for an extended period allowing additional joiners to be added in turn This lets you press the adder RESET NET ID button...