Installing Outside Air Kit
Model HD5030-TV is supplied with the component parts for outside combustion with the exception
of the 4" flex duct. It is recommended that the outside air system be used whenever possible.
Connect 4" Class-1 Flex duct or Metal Vent to duct collar on both sides of firebox; run ducts to
fresh air source and terminate using duct termination caps. The outside air can be opened by
pushing control knobs toward back of fireplace and closed by pulling towards front (Refer to
figure 8.1).
Finishing the Wall
Finish the wall with the material
of your choice. Do not install a
combustible mantle or other
combustible projection above the
fireplace opening unless it is a
minimum of 12 inches above top
of fireplace opening. (Figure 8.2)
Caution: All joints between the finished wall and the fireplace surround (Top and Sides)
can only be sealed with non-combustible material. Only non-combustible material can
be applied as facing to the fireplace surround. (Figure 8.2)
Hearth Extension
A Hearth Extension may be installed. But it is not required for vented gas fireplaces.
8
STUD
FINISHED
WALL
NON-COMBUSTIBLE
SEAL JOINT
MANTLE
12" MIN
TOP OF
OPENING
Figure 8.2
CONTROL
KNOB
DUCT
TERMINATION
RAIN CAP
CAULKING
WALL
OUTER
CASING
DUCT
COLLAR
Figure 8.1
Connecting the Gas Line
Consult local building codes before gas line installation. This gas fireplace is designed
to accept a 1/2" male flare fitting attached to a 1/2" supply line. Have the gas line in-
stalled by a qualified service person in accordance with all building codes. Install gas
line to fireplace on the right side attaching gas line to the gas flex line inside the control
box accessed by opening the control box door.
2X4
HEADER
ONE ON LEFT SIDE &
ONE ON RIGHT SIDE
ONE ON LEFT SIDE &
ONE ON RIGHT SIDE