Summary of Contents for BARSCREENSENSOR

Page 1: ...BARSCREEN THE ULTRASOUND Instruction manual CREENSENSOR LTRASOUND SCANNER BY GOLDANALYTIX Instruction manual ENSOR OLDANALYTIX Instruction manual ...

Page 2: ...ptember 2020 Rev 1 09 20 2020 MARAWE GmbH Co KG All rights reserved Printed in the EU All brand names and product names in this manual are registered trademarks of the respective manufacturer or enterprise ...

Page 3: ...t Goldanalytix Contact 2 2 Introduction 2 3 Scope of supply 3 4 Ultrasound scanning 4 5 Scanning bars 5 6 Tips Tricks 10 7 Environmental and Disposal Instructions 11 8 More non destructive Gold Testing Devices by Goldanalytix 12 ...

Page 4: ... 29020439 We are looking forward to your contact 2 Introduction Congratulations on your purchase of the Goldanalytix BarScreenSensor the professional scanning device for precious metal bars and coins Important Please read this instruction manual thoroughly prior to the first use of the BarScreenSensor Please keep in mind that no testing method can detect every fake We will not assume any responsib...

Page 5: ...ents In the unlikely event that something is damaged or missing please contact Goldanalytix immediately for contact data see page 2 Ultrasound measuring device Ultrasound gel 3x AA Instruction manual Small suitcase 3 is delivered with the following elements In the unlikely event that something is damaged or missing please contact Goldanalytix Ultrasound measuring device Ultrasound gel 3x AA batter...

Page 6: ...ontrolled by a microprocessor and allows quick and precise measurement of the thickness and sound speed of materials This device consists of a transmission circuit a receive circuit a high frequency oscillator a CPU a screen and an For the connections between sample and measuring head the set contains Description 5 MHz 5 mm 1000 9999 m s 4 digit visualization 0 1 mm 1 2 225 0 mm steel 1 D 0 1 mm D...

Page 7: ...block on the device Press CAL to get to the calibration mode Wait until the display shows 4 0 mm which indicates that the calibration has finished After that the device will turn back to the selected speed and the measurement can begin Measurement 1 Testing with already known sound speed 1 Establishing the speed value We have summarized some values of the most important precious metals for you in ...

Page 8: ...e the thickness of various spots Now you can carry out the actual ultrasound measurement Apply enough ultrasound gel on the spot you want to measure and lay the measurement head onto it Now the device will give you the object s thickness In our example the value matches exactly with the previously established thickness This means that the selected sound speed of 4329 m s for this object at this sp...

Page 9: ...loys others of uncommon materials The sound speeds for those are not listed in our overviews and the online data sources sometimes differ significantly from each other In this case you have to choose the procedure that is explained as follows If you know that the material for example on the exterior edge is not pervaded by the normally centrally situated foreign metal bars you can establish the sp...

Page 10: ...correct because the previously selected sound speed is wrong This is why you now take off the measurement head from the bar and measure the objects thickness with calipers Use the arrow keys to adjust the thickness for the BarScreenSensor in a way that it matches with the actual thickness ...

Page 11: ...ou did in measurement 1 Saving the data The established value can now be saved on the device s memory In order to do so push STORE for 2 seconds to get to the save mode Push the up down buttons to select the save file In order to look at the saved data push STORE for 2 seconds when in normal mode and you will obtain the saved data Push STORE to exit the save mode ...

Page 12: ... regularly with the integrated circular blank 4 mm thickness Thin testing objects In case of the testing object features a thickness 20 mm measurement errors can occur Rough surfaces On rough embossed or otherwise uneven surfaces on the opposite side of the measured area inaccurate measured values can arise Wear of the measuring head Since the measuring head is made from plastics wear marks can ap...

Page 13: ...he household waste according to European regulations 1 but have to be disposed separately The symbol on the dustbin indicates on the necessity of the separation from the household waste Please help to protect the environment Please asure that in case of not using the device anymore to give it to the corresponding garbage pick up Please inform yourself about the local waste calendar and your city o...

Page 14: ...gital screen www gold analytix com goldscreenpen electronic The GoldScreenCard tests coins and ingots by utilising the eddy current method The penetration depth is up to 4 mm The database included in the purchased software features values of most common coins and can be extended by the user with own values the perfect screencard gsc GoldScreenBox The GoldScreenBox measures the conductivity of coin...

Page 15: ...13 ...

Page 16: ...H Co KG Donaustaufer Str 378 Building 64 93055 Regensburg Amtsgericht Registergericht Regensburg HRA 9148 Seat Regensburg Personally liable partner MARAWE Verwaltungs GmbH Seat Regensburg Amtsgericht Regensburg HRB 14591 Dr Jonas Mark Dr Peter Raster Dr Stefan Weiß Phone 49 941 29020439 Fax 49 941 29020593 Mail gold analytix marawe de www gold analytix com Dr Jonas Mark Dr Peter Raster Dr Stefan W...