background image

Thank you for purchasing this Goldair product. Your product is warranted against faults and manufacture when used in
normal domestic use for a period of

one year.

In non-domestic use Goldair limits the voluntary warranty to

three

months.

Goldair undertake to repair or replace this product at no charge if found to be defective due to a manufacturing fault
during the warranty period.

This warranty excludes damage caused by misuse, neglect, shipping accident, incorrect installation, or work carried out
by anyone other than a qualified electrical service technician.

PLEASE KEEP YOUR RECEIPT AS THIS WILL HELP VERIFY YOUR WARRANTY.

The benefits to you given by this warranty are in addition to other rights and remedies available to you under a law in
relation to the goods or services to which this warranty relates.

In Australia, our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are
entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or
damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the
failure does not amount to a major failure.

In New Zealand this warranty is additional to the conditions and guarantees of the Consumers Guarantee Act (1993).

Goldair One Year Warranty 

(IMPORTANT: Please complete and retain this warranty card)

Name

Address

Place Of Purchase

Date of Purchase

Name Of Product 

Model Number

Attach a copy of the purchase receipt  to this warranty card

Due to continual design improvements, the product illustrated in this User Manual may differ slightly from the actual product.

Goldair – New Zealand
CDB Goldair
PO Box 100-707
N.S.M.C
Auckland, 0745

Phone +64 (0)9 917 4000
Phone 0800 232 633

www.goldair.co.nz

Goldair – Australia

CDB Goldair Australia Pty

PO Box 574

South Morang

Victoria, 3752

Phone +61 (0)3 9365 5100

Phone 1300 GOLDAIR  (1300 465 324)

www.goldair.com.au

One Year Warranty

Summary of Contents for Platinum GPORD02-18

Page 1: ......

Page 2: ...or repair 16 Do not twist kink or wrap the cord around the unit as this may cause the insulation to weaken and split Always ensure that all cord has been removed from any cord storage area and is unrolled before use 17 It is recommended that this heater is plugged directly into the wall socket or installed by a registered electrician in accordance with AS NZS 3000 2007 18 Do not remove plug from p...

Page 3: ...front and 150mm from the ends of the heater Ensure all packaging has been removed from the unit before use WARNING In order to avoid overheating do not cover the heater WARNING Never leave this heater unattended when powered on Unit Measurements Model No GPORD02 18 L1200 x W150 x H65mm 7 5kg Model No GPORD02 24 L1500 x W150 x H65mm 9 0kg Model No GPORD02 30 L1800 x W150 x H65mm 12 0kg SUPPORT AND ...

Page 4: ...east 150mm clearance from the ends of the heater to any adjacent wall and 200mm above the brackets to any ceiling or overhead structure fig 1 Fit the mounting bracket to the back of the heater by screwing the two wing screws fig 2 through the mounting bracket into the slots on the back of the heater and securely tighten them in place as shown in fig 3 and fig 4 Do not secure a bracket to the contr...

Page 5: ...he brackets on the heater to the brackets on the wall at the desired angle Do not point the heater at the ceiling Installation Guide Fig 5 CEILING MOUNTING Make sure the heater is unplugged before installing Position the heater within one metre of a wall socket Do not mount in front of or below the wall socket It is recommended that the heater is mounted at least 2m above the ground Ensure there i...

Page 6: ...t the heater bracket to the secured brackets either facing straight down or at an angle provided that the edge of the heater is pointed away from any adjacent wall the ceiling or overhead structure Installation Guide CEILING MOUNTING CONTINUED Fit the mounting bracket to the back of the heater by screwing the two wing screws fig 2 through the mounting bracket into the slots on the back of the heat...

Page 7: ...the risk of burns scalds fires or other damage to persons PROOF OF PURCHASE To receive warranty retain receipt as proof of purchase Refer to back of booklet WARNING Keep all objects at least 1 metre from the front and 150mm from the ends of the heater WARNING In order to avoid overheating do not cover the heater WARNING Never leave this heater unattended when powered on REMOTE CONTROL FUNCTIONS Th...

Page 8: ...der the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guarantees o...

Page 9: ......

Reviews: