INSTRUCTIONS FOR USE CONTINUED

b.Hepa outlet filter

1.) Open the cover by pressing the front cover release and lifting up
2.) Take out the Hepa outlet filter and clean or replace.

Please note: 

The sponge filter material in the vacuum that sits above the Hepa filter will became dusty over time. 
This is normal and will not affect the performance of the filter. If the sponge filter is so dusty that suction 
does not return to 100%, then we suggest that the filter be removed then rinsed under water and 
allowed to air dry for 24 hours. Do not air near the fire or high temperature objects. This should be done 
once every six months or when suction appears to be reduced.

The Hepa filter should also be rinsed under warm water when the suction of the vacuum appears to be 
reduced or every 6 months, which ever occurs first.  

Note:

The suction hole must be open and free of any obstructions at all times. Otherwise, the motor will 
overheat and may become damaged.

Important:

All filters should be checked regularly for signs of damage, preferably after each cleaning task. The 
filters must be replaced immediately if they become damaged. Always disconnect the vacuum from the 
electrical outlet when checking the filters.

1

2

Outlet filter grill

SUPPORT AND TECHNICAL ADVICE

North Shore City, Auckland, New Zealand

Monday – Friday 8am-5pm

Phone: 0800 232 633

Website: www.goldair.co.nz

Summary of Contents for GVC400

Page 1: ...Vacuum Cleaner Model GVC400 OPERATING INSTRUCTIONS GVC400 220 240V 50Hz 2000W Vacuum Cleaner ...

Page 2: ...ner when plugged in Unplug from outlet when not use and before servicing Use outdoors or on wet surfaces Never use this appliance for any purpose other than its intended use This appliance is for household use only This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they are supervised ...

Page 3: ...Air Intake Duct Wheel Power On Off Wand Storage Clip Cord Rewind Bag Full Indicator Increase Power Decrease Power Power Indicator Lights Front Cover Release Telescopic Tube Crevice Tool Floor Brush ...

Page 4: ...ush Adjust the telescopic tube to the desired length Variable suction control Once all attachments are in place unwind the entire length of the power cord and insert the plug into the wall outlet A yellow mark on the power cord shows the maximum ideal cable length Note Do not pull the power cord beyond the red mark 1 Insert the power plug into the wall outlet 2 Press the power on off button to tur...

Page 5: ... for approximately 1 hour To restart plug the vacuum into the wall outlet and turn the vacuum cleaner back on Change dust bag 1 Open the cover by pressing the front cover release and lifting up 2 Remove the dirty dust bag by sliding out and replacing with a new one Removing cleaning pre motor filter and Hepa outlet filter Warning Always unplug the unit from electrical outlet before removing the du...

Page 6: ...ts This should be done once every six months or when suction appears to be reduced The Hepa filter should also be rinsed under warm water when the suction of the vacuum appears to be reduced or every 6 months which ever occurs first Note The suction hole must be open and free of any obstructions at all times Otherwise the motor will overheat and may become damaged Important All filters should be c...

Page 7: ...the time of purchase It is in your interest to make sure this is done If the product is to be replaced cannot be repaired then that replacement will be of the same or similar product or accessory excluding packaging instruction card etc Where a replacement product is supplied this shall be guaranteed for the balance of the original warranty period Any model that is no longer available will be repl...

Reviews: