background image

Operating your Fan

Mid

MID

Warning: Unplug the appliance before
filling and cleaning.

Press the water tank handle button to take
out the water tank.
(Please refer to picture 1).

Fill the water tank with water, then place
the water tank back in the machine. Please
ensure that the water tank has been
securely fastened to the back cover.

(Please refer to picture 2).

Put the machine on a stable surface, insert
the plug into the socket. A buzzer will
sound

(‘Beep Beep’), the power icon will

light up on the screen, the machine is now
in standby mode.
(Please refer to picture 3).

Press on/off button to start the fan.

Picture 1

Picture 2

Picture 3

This

unit

features

four

functions:

misting fan, photocatalyzer, ionizer and
box fan in

one. You can use these

functions

at

the

same

time

or

separately.

Misting function

: Using high frequency 

(HF) vibration (Frequency 1.7 MHz or 
2.4MHz, which is inaudible and poses no 
harm to human body) the ceramic misting 
plate breaks up the water droplets, 
creating an elegant dry mist, without the 
need to heat or add any chemical agent. 

Ionizer function: 

Negative ions can 

refresh the air by neutralising positive

ions. Air pollution is made up of many 

positive ions (solid particles, bacteria and 
chemical fog). When they combine, the 
positive and negative ions attract which 
can make the pollutants drop out of the 
air.

Photocatalyst function:  

The blue piece 

at the base of the fan bottom houses the 
photocatalyst. It can decompose  noxious 
gases, inorganic compounds, inhibit the 
growth of the bacteria and the activity of 
viruses to supply fresh air.

Summary of Contents for GCMF220

Page 1: ...Operating Instructions 2 5L Misting Fan Item GCMF220 ...

Page 2: ...ildren with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they are supervised or have been given instruction concerning the use of the Fan by a person responsible for their safety 16 Never place appliance close to radiant heat source 17 Never operate in areas where petrol paint or other flammable liquids are used or stored 18 Never use the appliance to ...

Page 3: ...l buttons 2 Digital screen 3 Control panel 4 Misting plate 5 Rotating air guide 6 Front cover 7 Water level window 8 Bracket 9 Handle 10 Back guard 11 Water tank 12 Drain cover 13 Swivel castor 14 Back cover 15 Power cord ...

Page 4: ... the buttons on the operating panel with the exception of the child lock and screen off functions which are not on the remote control Display Screen 1 Misting icon 2 Power on icon 3 Wind speed icon 4 Timer icon 5 Ion function icon 6 Rotation icon 7 Fan function icon Buttons on the panel On Off button Wind speed button Mist button Ion function button Rotate Child lock function button Timer Screen O...

Page 5: ... photocatalyzer ionizer and box fan in one You can use these functions at the same time or separately Misting function Using high frequency HF vibration Frequency 1 7 MHz or 2 4MHz which is inaudible and poses no harm to human body the ceramic misting plate breaks up the water droplets creating an elegant dry mist without the need to heat or add any chemical agent Ionizer function Negative ions ca...

Page 6: ...so you can use it as humidifier ION Press the ION button to start the ION function Ion function icon will be light up on the screen Press it one more time and the Ion function will stop and the Ion function icon turns off ROTATE CHILD LOCK While the fan function is on press the ROTATE button to start rotating the rotation icon will be lit on the screen Press it one more time the rotation will stop...

Page 7: ...aning water tank Take out the water tank and rinse with clean water then pour out the water and wipe the tank with a clean cloth Cleaning misting box and misting box cover Pull out the mist tube from the mist box cover then take out the mist box and clean it see picture 1 Remove the scale on the mist plate and mist box with a soft brush then flush with clean water Drain the water and dry it with a...

Page 8: ...ng plate cover Remove the 2 screws from the misting plate base Pull out the misting plate base Pull out the front air louvre Clean each component with a soft cloth and re assemble Cleaning the fan blade and back guard Remove both screws on the back guard and take the net clip off Take the back guard off Remove the nut and nut washer from the motor axle Take the fan blade off Wash these parts and d...

Page 9: ... the holder Re install all these parts in reverse order Please clean the unit body as required Clean the unit body Wipe the machine with soft wet cloth Use a mild neutral detergent for stubborn stains DO NOT use any corrosive cleaners such as gas or alcohol to clean the plastic parts of the machine Put the machine into the box and keep it in a dry with good air circulation place To avoid risk of e...

Page 10: ... under the Australian Consumer Law You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure In New Zealand this warranty is additional to the conditions and guarantee...

Reviews: