Setup Procedure
(QUAVAR
-
PI & Metal Detector)
Once you have assemble the attachment to the device.
Clip it to the waist band of your harness, now you are
ready to tune your Detector To the QUAVAR
-
PI. It is a
very simple procedure. We are providing you with a
series of setting to suit Minelab pulse induction detec-
tors series. Just fallow the steps.
Note
: For the best tactile perception, secure the haptic
transducer underneath your harness on the chest area
for maximum body contact.
Connect the QUAVAR
-
PI to your detector by in-
serting the 6.5mm male jack from the audio cable
of the device into your detector power pack or
battery audio output female jack.
Next turn on both machines and let the detector
go through its tuning cycle. On the QUAVAR
-
PI
adjust the volume of its external speaker to a
comfortable level. The haptic transducer activates
automatically when the device is turned to the ON
position.
SD & GP Series
:
On your detector adjust the Audio Pitch (TONE).
With the SD & GP series the TONE level is to be
set to about 3/4 of the way up. Use the QUAVAR
-
PI audio extension cable (GT3021)
.
SDC Serie
:
The SDC 2300 has two audio pitch settings, High
and Low. For the Quavar
-
PI to function properly
the detector has to be set to the
LOW
Audio Pitch
(Tone) setting.
GPX Series
:
With the GPX 5000 it is important to set the Audio
Tone to 43 or under so as not to overload the
QUAVAR
-
PI. Do not lower the setting below 40 or
raise the setting above 45.
GPZ Serie:
With the GPZ 7000 it is important to set the
Threshold Pitch to between 65 to 70. It has a pre
-
set setting of 53.