MACHO POP
5
MODELS: 2553EX & 2554EX
Setting the Amount of Popping Oil with a Gold Medal BIB
System
In March 2003, we introduced the model 2257EX with the E-Z Set control.
Note: When connecting the bag-in-box
system, you must be sure to connect the
bag connectors as shown in the picture
to the left.
With this system, it is not necessary to set a timer. To adjust the oil amount, follow these
instructions:
Holding the RED
Oil Dispense
push button (on the popper) down while turning on the
Oil System
Master
switch (on the popper) puts the unit in the program mode. The oil light (on the popper) will
start to blink off and on indicating that the timer is in the program mode.
When in the program mode press and release the oil
Dispense
switch to start the oil flowing.
When the correct amount of oil has been dispensed into the measuring cup push the oil
Dispense
switch again to stop the oil flow. The oil amount can be “topped off” by pushing the oil
Dispense
switch on/off as many times as needed to finalize the oil amount. Turning the
Oil
System Master
switch off and then back on puts the unit in the regular mode. The unit will now
dispense the “programmed” amount of oil when the oil
Dispense
switch is pushed. The oil light
will light only when the oil pump is on.
You will need to perform this procedure with the oil lines full of oil. Otherwise, you are setting both
the amount of oil that goes in the kettle and the amount of oil required to fill the lines. Just fill the
lines using the process above, then reset the amount as described above.
NOTES:
Model 2257DX is has the capability of “remembering” two different settings for poppers with the
“Salt/Sweet” option or “Flexi-Pop option.
- For Salt/Sweet models, just put the switch in the “salt” position, and set the oil amount as
described above. Then put the switch in the “sweet” position and repeat the setting procedure. The
pump will remember both settings.
- For Flexi-Pop models, just put the “Load” switch in one position, 32oz. for example, then set the oil
amount. Then put the load switch in the other position, 18oz. for example. And repeat the setting
procedure.
- Model 2457 is the heated line option for the 2257EX pump.
The dead-leg connector
(With only one hose
connected to it) must be
installed on the top box.
The Pass-thru connector
(With two hoses
connected to it) must be
installed on the bottom
box.
The Pass-thru connector
(With two hoses
connected to it) must be
installed on the bottom
box.
a