background image

 

 

KZ25 Pump Head User’s Guide 

 

15#

24#

35#

36#

FASTENING 

SCREW

 

Figure 4. Fastening Screws Adjustment 

Note: 

The fastening screw is for adjusting the gap between compression 

block and tubing container to hold the tubing. It does not adjust flow rate. 
 
To check the gap between compression block and tubing retainer, put one 
end of tubing into water and pump air into tubing from the other end. There 
should be no bubbles coming out from tubing on the end in water. 
Otherwise, it means the gap is too small. 
 

6.2

 

Pump Head Installation 

1)  Be sure the pump drive is turned off.   
2)  Mount the mounting panel on the drive. 
3)  Align the shaft tang of the pump head to the coupler of the drive. 
4)  Tighten the mounting screws to secure the pump head on the 

drive. Ensure the tightness of the two tightening screws is the 
same and should not be too tight in order to prevent noise due to 
deformed housing. 

Summary of Contents for KZ25

Page 1: ...GOLANDER PUMP KZ25 PPS PC Pump Head User s Guide info golanderpump com http golanderpump com 1 678 587 8806...

Page 2: ...e power the pump off before installing external control devices Warning This product is not designed for nor intended for use in patient connected applications including but not limited to medical and...

Page 3: ...ith high torque such as WT S WT F BT100S 1 BT100F 1 Mount the pump head using the 2 screws provided The pump head is stackable HOUSING LEVER COMPRESSION BLOCK TUBING RETAINER MOUTING SCREWS SHAFT TANG...

Page 4: ...hickness 2 5mm Suitable Tubing Type Silicone pharmed etc Speed Range 0 600 rpm Flow Range 0 6000 mL min Channels 1 Output Pressure 0 14Mpa No of Rollers 3 304 stainless steel Case Material PC Polycarb...

Page 5: ...NG GUIDE BLOCK COMPRESSION BLOCK GUIDE SLOT Figure 3 Remove Compression Block and Load Tubing 3 Load the tubing on the rollers and the two V shaped slots of the tubing retainers Then put the compressi...

Page 6: ...and pump air into tubing from the other end There should be no bubbles coming out from tubing on the end in water Otherwise it means the gap is too small 6 2 Pump Head Installation 1 Be sure the pump...

Page 7: ...ure 5 Pump Head Installation Note When stack another pump head to it please align the shaft tang of the second pump head to the shaft slot of the first pump head and use provided screws to secure the...

Page 8: ...nnections to make sure there is no leakage Keep the pump head dry 2 Do not use chemical solvents to clean the head 3 As time goes on the flow rate will slightly change Please adjust the drive speed or...

Reviews: