background image

 

 

KZ25 Pump Head User’s Guide 

1

 

Safety Cautions 

Warning

: Please read through this user’s guide carefully before 

operating the pump head.   

 

Danger

: Remove the power from the pump before mounting or 

unmounting pump head to the drive. 

Danger

: Remove the power from pump before attempting any 

maintenance or any cleaning operation is started. 

Danger

: Turn drive off before removing or installing tubing. Fingers or 

loose clothing could get caught in drive mechanism. 

 

Warning

:  Tubing breakage may result in fluid being sprayed 

from pump. Please check the tubing frequently and change the 

tubing in time. 

Warning:  Please power the pump off before installing external control 

devices. 

Warning

: This product is not designed for, nor intended for use in patient 

connected applications; including, but not limited to, medical and dental 
use. 
 

Note: 

  Only use matched tubing with the pump head to ensure optimum 

performance. Use of other tubing may void applicable warranties. 

  Release the tubing loading levers if the drive stopped for a long 

time to prevent the rollers from squeezing the tubing all the time.   

  Change the squeeze section of the tubing in time to extend its 

lifetime. 

  When tubing breakage occurs, please use a mild detergent 

solution to clean the pump head. Do not immerse nor use 
excessive fluid. Please check if the rollers can still rotate smoothly. 
If not, please stop the drive to prevent it from damaging the pump 
head. 

Summary of Contents for KZ25

Page 1: ...GOLANDER PUMP KZ25 PPS PC Pump Head User s Guide info golanderpump com http golanderpump com 1 678 587 8806...

Page 2: ...e power the pump off before installing external control devices Warning This product is not designed for nor intended for use in patient connected applications including but not limited to medical and...

Page 3: ...ith high torque such as WT S WT F BT100S 1 BT100F 1 Mount the pump head using the 2 screws provided The pump head is stackable HOUSING LEVER COMPRESSION BLOCK TUBING RETAINER MOUTING SCREWS SHAFT TANG...

Page 4: ...hickness 2 5mm Suitable Tubing Type Silicone pharmed etc Speed Range 0 600 rpm Flow Range 0 6000 mL min Channels 1 Output Pressure 0 14Mpa No of Rollers 3 304 stainless steel Case Material PC Polycarb...

Page 5: ...NG GUIDE BLOCK COMPRESSION BLOCK GUIDE SLOT Figure 3 Remove Compression Block and Load Tubing 3 Load the tubing on the rollers and the two V shaped slots of the tubing retainers Then put the compressi...

Page 6: ...and pump air into tubing from the other end There should be no bubbles coming out from tubing on the end in water Otherwise it means the gap is too small 6 2 Pump Head Installation 1 Be sure the pump...

Page 7: ...ure 5 Pump Head Installation Note When stack another pump head to it please align the shaft tang of the second pump head to the shaft slot of the first pump head and use provided screws to secure the...

Page 8: ...nnections to make sure there is no leakage Keep the pump head dry 2 Do not use chemical solvents to clean the head 3 As time goes on the flow rate will slightly change Please adjust the drive speed or...