![GOK Caramatic DriveOne Assembly And Operating Manual Download Page 17](http://html1.mh-extra.com/html/gok/caramatic-driveone/caramatic-driveone_assembly-and-operating-manual_2239122017.webp)
Caramatic DriveOne
Artikel-Nr. 71 813 50
17 / 36
START-UP
1. Start the system by slowly opening the gas
supply while the shut-off fitting of the
connected consuming devices remains
closed. Observe the assembly and operating
manual of the connected consumption
equipment!
Activate the crash-sensor-pendulum the first
time you start the system:
2. By pushing the green push button on the
crash-sensor-pendulum.
Apply the adhesive accompanying the
product to a visible area of the Caramatic
DriveOne.
TROUBLESHOOTING
Fault cause
Action
Gas smell
Leaking LPG is extremely
flammable.
Can cause explosions.
Close the gas supply.
Do not use any electric switches.
Do not use a phone in the vehicle.
Ventilate rooms well.
Shut down the LPG system.
Contact a specialised company.
No gas flow.
Open the tank valve or the shut-off fittings.
Pressure regulator is defective, replace.
Activation of the crash-sensor-pendulum see START-UP.
Abnormal flame pattern of
non-adjustable pressure
regulator
Compare the nominal outlet pressure of the pressure
regulator with the nominal inlet pressure of the connected
consuming device:
if they do not correspond, replace the pressure regulator
or the gas appliance
Safety two stages regulator
S2SR reacted.
Allow short bursts of gas to escape from the gas
equipment to achieve pressure compensation.
If no pressure compensation is achieved, replace the
pressure regulator.
SHUT-DOWN
Close the tank valve and then the shut-off devices of the consumer unit. When the system is
not used, all valves must be kept closed.
RESTORATION
If the actions described in TROUBLESHOOTING
do not lead to a proper restart and if there is
no dimensioning problem, the product must be sent to the manufacturer to be checked. Our
warranty does not apply in cases of unauthorised interference.