2
| Deutsch
11
| English
www.goebel-group.com
3. Function settings
Read the following particularly important notes carefully when you are ready to start
using the function settings. Very important: GO-BR1 and GO-BR2 have a stroke setting
function, the GO-TR1 does not.
3.1
The function is set at the factory
GO-BR1: Stroke: (B) 0.83 inches ; Riveting mode: conventional riveting mode (D).
GO-BR2: Stroke: (B) 1.0 inches ; Riveting mode: conventional riveting mode (D).
Before changing the function (setting/switch), please pay attention to the riveting, the
working and riveting condition.
➀
Stroke control
➁
Mode indicator light
➂
Button/ Trigger
L
D
S S
B
B
3
2
1
Stroke setting
Press the button
➂
to enter the stroke adjustment. With each short press, the stroke
indicator lights up green.
GO-BR1, stroke indicator: S = 0.59" stroke, indicator B= 0.83" stroke.
GO-BR2, stroke indicator: S = 0.79" stroke, indicator B= 1.0" stroke.
3.2
Setting the riveting mode (Important notes before setting the riveting mode)
Before switching the riveting mode, please observe the specifications of the rivet, the
working conditions and the rivet condition. Select the correct riveting mode. There are two
riveting modes: the self-locking riveting mode (L) and the conventional riveting mode (D).
Self-locking rivet mode: Mode indicator light
➁
(L) green light is on.
Normally, after the rivet has been inserted into the nosepiece, pressing the trigger
automatically locks the rivet and sends it to the exact position of the nosepiece. Pressing
the trigger again completes the riveting process. This mode is suitable for riveting in difficult
positions or in situations where rivets cannot be fixed and fall off easily.
Assembly line operation is not recommended!
Conventional riveting mode: Mode indicator light (D) is green.
Normally the rivet is inserted into the work piece, the nosepiece of the riveting tool is placed
on the mandrel and then the trigger is pulled to complete the riveting process. Due to
bending of the rivet mandrel or not properly fixing the rivet can lead to rivets falling out,
which is not recommended.
Switching the riveting mode
Function in factory preset state, long press on button
➂
for 1.5 seconds, the mode indicator
light (L) is green and the riveting mode is switched to self-locking mode. Press button
➂
again for 1.5 seconds and the mode indicator light is green, the rivet is back in conventional
mode (D). When changing the mode from (L) to (D), please make sure that the riveting
process 2x (L) is completed, otherwise it will not be possible to change to mode (D).