Modeling Lamp Settings

1.  Multi-group displays in the TTL mode

    

1.1

 

 

Press the group button to choose the group, turn the select dial, and the FEC 

          value will change from -3 to ~3 in 0.3 stop increments. Press the <

SET

> button 

          to confirm the setting.

    

1.2

 

 

Press <

ALL

> button to choose all groups’ FEC value, turn the select dial, and all 

          groups’ FEC value will change from -3 to ~3 in 0.3 stop increments. Press 

          <

ALL

> button again to confirm the setting.

 2. One-group displays in the TTL mode

    Turn the select dial and the group’s power output value will change from -3 to ~3 in 

    0.3 stop increments.

1. 

 When displaying multiple groups, press the <

MOD

    button to control the ON/OFF of the modeling lamp.

2. 

 Press the group button to choose the group when 

    displaying multiple groups or when displaying one-group, 

    press the <

MOD

> button to control the ON/OFF of the 

    modeling lamp (note: The models that can use one-

    group to ON/OFF the modeling lamp are as follows: 

    GSII, SKII, QSII, QDII, DEII, DPII series, etc. The 

    outdoor flash AD200 and AD600 can use this function 

    after upgrade. The new arrivals with modeling lamps can 

    also use this function.). 

Flash Exposure Compensation Settings

1. 

 In the multi flash (TTL and M icon are not displayed).

2.  

The three lines are separately displayed as power output 

    value, Times(flash times) and Hz (flash frequency).

3. 

 Turn the Select Dial to change the power output value 

    from Min. to 1/4 in integer stops.

4. 

 Short press the Times button can change flash times. 

    Turn the select dial to change the setting value.

5. 

 Short press the THz button can change flash frequency. 

    Turn the select dial to change the setting value.

Multi Flash Settings (Output Value, Times and Frequency)

Setting the Flash Trigger 

Setting the Flash Trigger 

CH1

A

B

C

D

E

--

ON

1

/64

--

--

--

CH/Zm Times

Hz

MOD

3 Times

1 Hz

MULTI

6.  

Until all the amounts are set. Or during any value setting, short press the <

MODE

    button to exit the setting status. No values will blink.

7. 

 In the multi flash setting submenu, short press the <

MODE

> button to return to main 

    menu when no values are blinking.

Note: 

As flash times are restricted by flash output value and flash frequency, the flash 

times cannot surpass the upper value that permitted by the system.

        The times that transported to the receiver end are a real flash time, which is also 

related to the camera’s shutter setting.

CH1

CH/Zm

SYNC

MOD

A

B

C

D

E

ALL

--

M

1

/128

--

--

--

- 38 -

- 37 -

Summary of Contents for XProC

Page 1: ...hina Add A4 Building A4 Xinhe Huafa Industrial Zone Fuzhou RD West Fuyong Town Baoan District Shenzhen 518103 China Tel 86 755 29609320 8062 Fax 86 755 25723423 E mail godox godox com GODOX Photo Equi...

Page 2: ...Compatible Camera Models Technical Data Restore Factory Settings Firmware Upgrade Attentions Caring for Flash Trigger Contents Foreword Thanks for your purchase of this XProN wireless flash trigger T...

Page 3: ...ies into a fire or apply direct heat to them Do not attempt to insert batteries upside down or backwards Batteries are prone to leakage when fully discharged To avoid damage to the product be sure to...

Page 4: ...ttery compartment lid of the flash trigger and insert two AA batteries separately Battery Level Indication Check the battery level indication on the LCD panel to see the remaining battery level during...

Page 5: ...will be displayed on the LCD panel Long press the Using the Flash Trigger 3 As a Wireless Original Flash Trigger Take SB910 as an example 3 1 Turn off the camera and mount the transmitter on camera h...

Page 6: ...the camera flash and the flash trigger both turn red synchronously Note As the studio flash s minimum output value is 1 32 the output value of the flash trigger should be set to or over 1 32 As the st...

Page 7: ...de Slide the power switch to ON and the AF lighting is allowed to output When the camera cannot focus the AF assist beam will turn on when the camera can focus the AF assist beam will turn off Power S...

Page 8: ...mode 3 When setting the group to 16 groups 0 F there is only manual mode M 4 Long press the MODE button for 2 seconds until LOCKED is displayed on the bottom of the LCD panel which means the screen is...

Page 9: ...mps can also use this function Flash Exposure Compensation Settings 1 In the multi flash TTL and M icon are not displayed 2 The three lines are separately displayed as power output value Times flash t...

Page 10: ...he camera Press the shutter for shooting 1 2 Long press the TCM button and the flash value in TTL mode will transform into power output value in M mode The displayed minimum value is the set Min value...

Page 11: ...function consumes power quickly APP Only send triggering signal when camera is shooting control the flash s parameters by smartphone APP C Fn Ver9 2 GROUP LCD SYNC APP CLEAR SHOOT Setting Signs ON OFF...

Page 12: ...D600 The power output values in the M mode which are transformed from TTL mode being subjected to the master flash when mixing Compatible Flash Models Receiver X1R N XTR 16 XTR 16S Flash AD600 series...

Page 13: ...Power supply Flash Exposure Control TTL autoflash Manual flash Stroboscopic flash Function High speed sync Second curtain sync Flash exposure compensation Flash exposure lock Focus assist Modeling la...

Page 14: ...to MF If so set it to AF 3 Signal disturbance or shooting interference Change a different channel on the device 4 Operating distance limited or flash missing Check if batteries are exhausted If so ch...

Reviews: