Godox DPIII Series Instruction Manual Download Page 7

Tube Replacement

   

Shut down the power and remove the power cord before replacing the flash tube 
and wear insulated gloves. Then, loosen the iron wire on the tube, keep a balanced 
hold on the two feet of the flash tube and pull out the old tube gently. Take down the 
feet casing from the old tube and put it on the new one. Hold two feet of the new 
tube, and target directly towards the two copper outlets, then push them slightly in. 
Twine the iron wire on the stainless steel sheet to fix the flash tube.

TECHNICAL DATA

5600±200K

100-120V~50/60Hz or 200-240V~50/60Hz

OFF, 4.0~10.0

(

1/64~1/1)

150W

Sync cord, Test button, Slave triggering, Wireless control port

1/2000~1/800s

5V

5V/200mA (only for Godox receiver)

       

Model

Max Power (WS)

Guide Number(m ISO 100)

Color Temperature

Operating Voltage

Power Output Control

Modeling Lamp (W)

Triggering Method

Flash Duration

Parameters Output from 

the Sync Cord Jack 

Parameters Output from  

the USB Port

Fuse

Recycle Time

Dimension

Net Weight

2.54kg

2.69kg

3.2kg

3.3kg

8A

5A

1s

Flash diameter12.5CM

height of flash with handle 21.5CM,

length of flash with lamp cover 

47.5CM

length of flash with lamp cover 

42CM

DP400 III

400Ws

65

DP600 III

600Ws

80

DP800 III

800Ws

88

DP1000 III

1000Ws

92

MAINTENANCE

Shut down the device immediately when it works abnormally and find out the reason.
Avoid sudden impacts and the lamp should be dedusted regularly.
It is normal for the lamp to be warm when in use. Avoid continuous flashes if unnecessary.
Maintenance of the flash must be performed by our authorized maintenance department 
which can provide original accessories. The flash-tube and the modeling lamp are 
user-replaceable. Replacement tubes and lamps can be obtained from the manufacturer.
This product, except consumables e.g. flash tube and modeling lamp, is supported with 
a one-year warranty.
Unauthorized service will void the warranty.
If the product had failures or was wetted, do not use it until it is repaired by professionals.
Disconnect the power when cleaning the flash or when changing the flashtube / 
modeling lamp.
Changes made to the specifications or designs may not be reflected in this manual.

- 19 -

- 20 -

-Connect the equipment into an outlet on a circuit different from that to which the 
receiver is connected. 

Any Changes or modifications not expressly approved by the party responsible for 
compliance could void the user's authority to operate the equipment. 

-Increase the separation between the equipment and receiver. 

-Reorient or relocate the receiving antenna. 

-Consult the dealer or an experienced radio/TV technician for help. 

Note: 

This equipment has been tested and found to comply with the limits for a Class B 

digital device, pursuant to part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference in a residential installation. 
This equipment generates uses and can radiate radio frequency energy and, if not 
installed and used in accordance with the instructions, may cause harmful interference 
to radio communications. However, there is no guarantee that interference will not occur 
in a particular installation. If this equipment does cause harmful interference to radio or 
television reception, which can be determined by turning the equipment off and on, the 
user is encouraged to try to correct the interference by one or more of the following 
measures: 

This device complies with part 15 of the FCC Rules. Operation is subject to the following 
two conditions: (1) This device may not cause harmful interference, and (2) this device 
must accept any interference received, including interference that may cause undesired 
operation. 

FCC

Summary of Contents for DPIII Series

Page 1: ...4 1st to 4th Floor Building 2 1st to 4th Floor Building 4 Yaochuan Industrial Zone Tangwei Community Fuhai Street Bao an District Shenzhen 518103 China Tel 86 755 29609320 8062 Fax 86 755 25723423 E m...

Page 2: ...ireless X system 1 2000 to 1 800 second short flash duration and fast recycling with 150W modeling lamp Wireless control of the flash power ratio needed a receiver modeling lamp and buzzer as well as...

Page 3: ...se of babies otherwise it may lead to visual impairment Disconnect from the power supply when it will not be used for an extended period CAUTION Avoid sudden impacts as this can damage the flash tube...

Page 4: ...is for different photo umbrellas to put in To uninstall the standard reflector press the release button on the flash head and turn the standard reflector counter clockwise to take it out as illustrat...

Page 5: ...model button No optical control S1 or S2 is not displayed on the LCD panel indicating the slave triggering function is shut down Optic S2 Secondary Unit Setting Press S1 S2 button so that this flash...

Page 6: ...u can press the camera shutter release button to trigger the flash You can also hold the transmit end at hand to control your off camera flash The flash unit is built in with a Wireless Control Port s...

Page 7: ...r This product except consumables e g flash tube and modeling lamp is supported with a one year warranty Unauthorized service will void the warranty If the product had failures or was wetted do not us...

Reviews: