![Godox DPIII Series Instruction Manual Download Page 7](http://html1.mh-extra.com/html/godox/dpiii-series/dpiii-series_instruction-manual_2238110007.webp)
Tube Replacement
Shut down the power and remove the power cord before replacing the flash tube
and wear insulated gloves. Then, loosen the iron wire on the tube, keep a balanced
hold on the two feet of the flash tube and pull out the old tube gently. Take down the
feet casing from the old tube and put it on the new one. Hold two feet of the new
tube, and target directly towards the two copper outlets, then push them slightly in.
Twine the iron wire on the stainless steel sheet to fix the flash tube.
TECHNICAL DATA
5600±200K
100-120V~50/60Hz or 200-240V~50/60Hz
OFF, 4.0~10.0
(
1/64~1/1)
150W
Sync cord, Test button, Slave triggering, Wireless control port
1/2000~1/800s
5V
5V/200mA (only for Godox receiver)
Model
Max Power (WS)
Guide Number(m ISO 100)
Color Temperature
Operating Voltage
Power Output Control
Modeling Lamp (W)
Triggering Method
Flash Duration
Parameters Output from
the Sync Cord Jack
Parameters Output from
the USB Port
Fuse
Recycle Time
Dimension
Net Weight
2.54kg
2.69kg
3.2kg
3.3kg
8A
5A
1s
Flash diameter12.5CM
,
height of flash with handle 21.5CM,
length of flash with lamp cover
47.5CM
length of flash with lamp cover
42CM
DP400 III
400Ws
65
DP600 III
600Ws
80
DP800 III
800Ws
88
DP1000 III
1000Ws
92
MAINTENANCE
Shut down the device immediately when it works abnormally and find out the reason.
Avoid sudden impacts and the lamp should be dedusted regularly.
It is normal for the lamp to be warm when in use. Avoid continuous flashes if unnecessary.
Maintenance of the flash must be performed by our authorized maintenance department
which can provide original accessories. The flash-tube and the modeling lamp are
user-replaceable. Replacement tubes and lamps can be obtained from the manufacturer.
This product, except consumables e.g. flash tube and modeling lamp, is supported with
a one-year warranty.
Unauthorized service will void the warranty.
If the product had failures or was wetted, do not use it until it is repaired by professionals.
Disconnect the power when cleaning the flash or when changing the flashtube /
modeling lamp.
Changes made to the specifications or designs may not be reflected in this manual.
- 19 -
- 20 -
-Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Any Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
-Increase the separation between the equipment and receiver.
-Reorient or relocate the receiving antenna.
-Consult the dealer or an experienced radio/TV technician for help.
Note:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful interference
to radio communications. However, there is no guarantee that interference will not occur
in a particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:
This device complies with part 15 of the FCC Rules. Operation is subject to the following
two conditions: (1) This device may not cause harmful interference, and (2) this device
must accept any interference received, including interference that may cause undesired
operation.
FCC