30
©Godiva Ltd. Our policy is one of continuous development. We therefore reserve the
right to amend specifications without notice or obligation.
Electrical Connections
Connect the engine control and warning light module to the vehicle electrical system with the multi-pin
plug (supplied with the unit, part number 60764). The connections used will vary according to the pump
specification.
Power to the system should be such that the minimum required system voltage is maintained
continuously throughout operation. System voltage dips of any duration may cause the interlocking
circuitry to inadvertently disengage the system compressor. Having a direct as possible wiring path to the
battery supply may help to mitigate this type of situation.
NB: Vehicle builder
–
use a 10 amp fuse in
the supply line