Manual Priming (if installed by the OEM)
Press the Manual Prime button to activate the primer.
Note: when prime is achieved, the primers will automatically disengage.
It is not possible to operate the primers if the pump pressure is above 0.75 bar.
If the pump pressure drops below 0.75 bar, the primers will not activate unless the
Manual Primer engage button is depressed.
Do not operate the pump for extended periods with the discharge valves closed. This
may cause the pump to overheat. On P2 and PC2 pumps a thermal relief valve is fitted
as standard to help prevent overheating.
Operation
– from a pressurised source, e.g. hydrant or vehicle tank
If water is supplied from a pressurised source then priming is not necessary.
P2 - High Pressure Operation
By moving the High/Low pressure selector lever to
–
Figure 26.
Left
– High pressure will be available to the hose reels
Low pressure also available at low pressure discharge
Figure 27.
Right
– Low pressure only available to hose reels
Low pressure also available at low pressure discharge
IMPORTANT