12
©Godiva Ltd. Our policy is one of continuous development. We therefore reserve the
right to amend specifications without notice or obligation.
INSTALLATION
1. Before installation check the pump for any transit damage.
2. Mounting Platform
If a mounting platform is fitted, note the bolt points (see drawing in fig.15 or 16) to
secure the pump to the vehicle chassis
–
Figure 3.
2. Priming System
Piston Primer Type
–
Connect two flexible pipes (25mm, 1inch internal dia.) to the discharge ports on each
primer.
Discharge can be piped to the ground.
Discharge can be piped back to main tank
– if no foam system is used.
Discharge can be piped to a separate holding tank.
Figure 4.
Piston primer discharge
–
connect
25mm
(1in)
flexible pipe. Length to be
sufficient
to
discharge
safely away from operator
Fastening bolt points
–
M16, high tensile cap
screws, four off