Godin 362105 Instructions Of Installation Download Page 6

6 | 

P a g e

 

 

 

Don’t  use  the  unit  if  the  glass  is  broken  or  cracked;  proceed  with  the  replacement  of  glass  before 
lighting.  

 

When loading the unit make sure that the fire is burning low. Do not open the door of the unit if it’s 
running  on  high,  or  if  large  flames  are  visible.  If  opening  the  door  when  the  flames  are  visibly  high, 
there is a risk they could leap outside the fire cavity.  

 

Always open the door gently, allowing the draught to stabilize and to avoid a down draught. 

 

 

 

GENERAL PRINCIPLES OF CONNECTION FOR REAR AND TOP FLUE OUTLETS (WHERE POSSIBLE) 

 
 

 

 
 
 
 

Summary of Contents for 362105

Page 1: ...models large panoramic heat resistance vitro ceramic glass heat resistance to 750 deg C Dimensions of loading opening cm 46x30 46x30 46x24 All mentioned models cast iron firebox All mentioned models manual regulation Weight 120kg 116kg 106kg Heat output 13kW 13kW 9kW Heating Volume 200 500m3 200 500m3 130 330m3 All mentioned models rate of normal combustion depending on fuel properties 3hrs All me...

Page 2: ...appropriate flue outlet connection to a chimney which must guarantee sufficient draught flow capacity is of the utmost importance It is of course preferable that this appliance be installed by a professional which knows of all relevant codes of practice and safety regulations and who can guarantee a flawless installation Line drawing for the Ecoval Ref 362105 ...

Page 3: ...3 P a g e Linedrawings for Le Cerval Ref 364101 Linedrawing for Le Cervalou Ref 364112 ...

Page 4: ...d must be very open angled The draught must range between 1 5mm WG and 2mm WG when burning normally and must drop at 0 5mm WG roughly when burning slowly If the draught is too high a damper should be fitted If the draught is insufficient check if the characteristics of the chimney comply with those prescribed in this paragraph If the cross section of the fireplace is too large the volume to be hea...

Page 5: ...e right hand side need to be a minimum of 30cm from the unit and made of non flammable materials The rear wall must not be of flammable materials If the rear wall is of a flammable material it must be protected sufficiently and effectively GENERAL INFORMATION When operating the unit do not open the door by hand use the operating tool supplied The units are designed to be burnt with the door in the...

Page 6: ...ing low Do not open the door of the unit if it s running on high or if large flames are visible If opening the door when the flames are visibly high there is a risk they could leap outside the fire cavity Always open the door gently allowing the draught to stabilize and to avoid a down draught GENERAL PRINCIPLES OF CONNECTION FOR REAR AND TOP FLUE OUTLETS WHERE POSSIBLE ...

Page 7: ...een utilized Use the Godin chimney cleaner Ref 0008 at the beginning and end of each season Clean the internal part of the appliance thoroughly without forgetting the top of the baffle plates It is important never to attempt to clean the glass of the unit while it is still hot THE IMPORTANCE OF FUEL Godin heaters have a thermal output close to 70 efficiency Never the less you must not forget that ...

Page 8: ...y a competent professional acting under his own responsibility In the interest of constant product improvement GODIN SA reserves the right to change specifications without notice These instructions will help you obtain the most effective performance from you appliance under normal operating conditions if any problems concerning your appliance should arise do not hesitate to contact your supplier w...

Page 9: ...9 P a g e ...

Page 10: ...10 P a g e ...

Page 11: ...11 P a g e ...

Page 12: ...rts Some parts have a longer guarantee 3 years for cast iron or steel heating body of our boilers for central heating Wood burning Inserts and closed fireboxes running with wood have a 5 year warranty only the heating body parts in direct contact with high temperatures and undergoing wear and tear described above have 1 year guarantee Only the parts s that are deemed to have failed will be covered...

Page 13: ...le for any installation assembly dismantling costs and consequential removal of the appliance Consequently Godin SA cannot be held responsible for any materials loss or human accidents being a result of incorrect installation non observing the legal provisions and regulations for example lack of ground connection incorrect draft of the chimney etc In order to constantly improve our products we res...

Reviews: