INSTRUCTIONS FOR THE INSTALLER 

 
Note: before the installation is carried out, ensure that the chimney is in good condition and will provide 
adequate draught. It is imperative that the diameter of the flue piping is not altered and is installed with 
180mm flue piping. 
 

 

The  installation  must  be  in  compliance  with  local  authorities  and  carried  out  by  a  competent 
professional. 

 

The factory fits the spigot at the rear of the appliance. It can be connected directly to a chimney by 
using a horizontal pipe. The chimney connection can also be taken off the top of the unit; this can 
be done by interchanging the covering plate and the spigot. 

Important:  

 

If  the  floor  is  made  of  flammable  materials  it  is  necessary  to  protect  it  with  some  form  of 
installation.  This  must  be  a  non-combustible  material  and  should  provide  40cm  clearance  in 
front of the stove. 

 

Preferably use enameled flue pipes, as their resistance to corrosion is remarkable. 

 

The flue pipes get hot; make sure they are away from any combustible materials.  

 

The walls on the left and the right hand side need to be a minimum of 30cm from the unit, and 
made of non flammable materials. 

 

The rear wall must not be of flammable materials. If the rear wall is of a flammable material, it 
must be protected sufficiently and effectively. 

 

GENERAL INFORMATION 

 

 

When operating the unit, do not open the door by hand, use the operating tool supplied. 

 

The units are designed to be burnt with the door in the closed position. 

 

Load the unit from the front door. 

 

The regulation of the combustion is done by the engraved positions situated on the front of the door. 
(Position 1 = slow, Position 2 = Moderate operation, Position 3 = Normal to high) 

 

For normal functioning use 3-4 logs set on position 2 or 3. 

 

For slow running, leave the fire until it has burned quite low, and then load with one or two logs and 
close the flap. It is always possible to add more logs to prolong the period of the combustion  of the 
heater. 

 

Do not load higher than 25cm. 

 

The operation of the fireplace depends on the kind of wood and the dryness of the wood. 

 

 

HOW TO USE THE UNIT 

 

Always follow the instructions. 

 

During  the  first  lighting  of  your  heater  use  small  loads  of  wood  to  verify  that  the  unit  is  functioning 
properly. 

 

Never use the unit as an incinerator. 

 

Only use the recommended fuel. 

Summary of Contents for 362105

Page 1: ...models large panoramic heat resistance vitro ceramic glass heat resistance to 750 deg C Dimensions of loading opening cm 46x30 46x30 46x24 All mentioned models cast iron firebox All mentioned models manual regulation Weight 120kg 116kg 106kg Heat output 13kW 13kW 9kW Heating Volume 200 500m3 200 500m3 130 330m3 All mentioned models rate of normal combustion depending on fuel properties 3hrs All me...

Page 2: ...appropriate flue outlet connection to a chimney which must guarantee sufficient draught flow capacity is of the utmost importance It is of course preferable that this appliance be installed by a professional which knows of all relevant codes of practice and safety regulations and who can guarantee a flawless installation Line drawing for the Ecoval Ref 362105 ...

Page 3: ...3 P a g e Linedrawings for Le Cerval Ref 364101 Linedrawing for Le Cervalou Ref 364112 ...

Page 4: ...d must be very open angled The draught must range between 1 5mm WG and 2mm WG when burning normally and must drop at 0 5mm WG roughly when burning slowly If the draught is too high a damper should be fitted If the draught is insufficient check if the characteristics of the chimney comply with those prescribed in this paragraph If the cross section of the fireplace is too large the volume to be hea...

Page 5: ...e right hand side need to be a minimum of 30cm from the unit and made of non flammable materials The rear wall must not be of flammable materials If the rear wall is of a flammable material it must be protected sufficiently and effectively GENERAL INFORMATION When operating the unit do not open the door by hand use the operating tool supplied The units are designed to be burnt with the door in the...

Page 6: ...ing low Do not open the door of the unit if it s running on high or if large flames are visible If opening the door when the flames are visibly high there is a risk they could leap outside the fire cavity Always open the door gently allowing the draught to stabilize and to avoid a down draught GENERAL PRINCIPLES OF CONNECTION FOR REAR AND TOP FLUE OUTLETS WHERE POSSIBLE ...

Page 7: ...een utilized Use the Godin chimney cleaner Ref 0008 at the beginning and end of each season Clean the internal part of the appliance thoroughly without forgetting the top of the baffle plates It is important never to attempt to clean the glass of the unit while it is still hot THE IMPORTANCE OF FUEL Godin heaters have a thermal output close to 70 efficiency Never the less you must not forget that ...

Page 8: ...y a competent professional acting under his own responsibility In the interest of constant product improvement GODIN SA reserves the right to change specifications without notice These instructions will help you obtain the most effective performance from you appliance under normal operating conditions if any problems concerning your appliance should arise do not hesitate to contact your supplier w...

Page 9: ...9 P a g e ...

Page 10: ...10 P a g e ...

Page 11: ...11 P a g e ...

Page 12: ...rts Some parts have a longer guarantee 3 years for cast iron or steel heating body of our boilers for central heating Wood burning Inserts and closed fireboxes running with wood have a 5 year warranty only the heating body parts in direct contact with high temperatures and undergoing wear and tear described above have 1 year guarantee Only the parts s that are deemed to have failed will be covered...

Page 13: ...le for any installation assembly dismantling costs and consequential removal of the appliance Consequently Godin SA cannot be held responsible for any materials loss or human accidents being a result of incorrect installation non observing the legal provisions and regulations for example lack of ground connection incorrect draft of the chimney etc In order to constantly improve our products we res...

Reviews: