Picture 8.3
: in n scenario C the correct stop position of the back label is 100mm minus the label length minus
½ gap length
Picture 8.4
: in n scenario D the correct stop position of the back label is 100mm minus the combined length of
all the labels and all the gaps, plus ½ gap length.
Stop position 2
Now you calculate stop position 2.
Stop position 2 relates to the front label on your product
.
= front label position
The procedure is the same, but now you start measuring from the front end of a front label:
Picture 9.1
: in scenario A the correct stop position of the front label is 100mm.