III.
Setting the rotation time:
After confirming the correct stop position in the menu, you enter the rotation time in seconds and confirm. The
rotation time is the time the product rotates after the label sensor has detected the end of the label. Two
seconds is a convenient value for most labels. You may decrease the rotation time to speed up each
application cycle as long as you ensure each label is transferred and firmly attached to the product before
rotation stops.
You are now ready to do a test cycle (paragraph 8.6).
Note
: the calculated stop positions are a good start. Tuning might be required once you start operating the
device.
8.4
Label settings (2-Label Mode)
I.
Selecting 2-Label mode:
-
Hold the “ ”button to enter the AP16
-F menu
-Select the program you want to use or edit with the the and buttons
-
hold the “M” button to open the settings
-Select your language with the and
buttons and confirm with the “M” button:
-Select 2-Label Mode and confirm: