BlueSense - DIP switch configuration - Differentiation motherboard
GO Systemelektronik GmbH Faluner Weg 1 24109 Kiel Germany Tel.: +49 431 58080-0
Fax: -58080-11
Page 50 / 55
www.go-sys.de
Appendix F - DIP switch configuration
DIP switch configuration Type I DIP switch configuration Type II
Type I is applicable for:
•
white switch slider
and
motherboard Version A
•
red switch slider
and
motherboard Version B
Type II is applicable for:
•
white switch slider
and
motherboard Version B
•
red switch slider
and
motherboard Version A
Appendix G - Differentiation motherboard Version A
B
The motherboard Version B is different from the motherboard Version A in that on the motherboard Version B
two additional jumper slots are mounted (X20 and X21)
. These jumper slots are located in the
lower left
corner
of the motherboard, visible after removing the front cover of the housing.
If these jumper slots exist, it is motherboard Version B.
If these jumper slots do
not
exist, it is motherboard Version A.
If the motherboard can not be clearly assigned, please contact GO Systemelektronik.
CAN-bus
S1
ON
OFF
ON
OFF
JP1
JP2
RS-232
S1
ON
OFF
ON
OFF
JP1
JP2
RS-485
ON
OFF
JP1
JP2
S1
ON
OFF
CAN-bus
S1
ON
OFF
ON
OFF
JP1
JP2
RS-232
S1
ON
OFF
ON
OFF
JP1
JP2
RS-485
ON
OFF
JP1
JP2
S1
ON
OFF
Jumper slot X20
Jumper slot X21