2.5.3 INSTALLATION IN HYBRID SYSTEM FOR DESIGNATED CIRCUITS
(
CONFIGURATION D
)
The TS-30 A can be installed between inverter (default) and a circuit panel supplied by a larger amp alternating power
supply (dominant).
1. Connect the inverter to terminals 7 and 8.
2. Connect the 30-amp branch circuit to 5 and 6.
3. Connect the designated circuit panel to the output terminals to connections 3 and 4.
The inverter will only supply the load in the absence of the 50-amp power supply, in which case, only the load designated
to the 30-amp branch circuit is supplied. The timer delay bypass switch on the TS-30 should be in the ON position.
3.
OPERATIONAL TESTING
READ AND FOLLOW ALL SAFETY INSTRUCTIONS
The following diagrams on pages 12-15 show how the IC Series inverter/charger is typically installed in a mobile RV application.
The diagrams show where the Inverter/Charger is installed and how the mobile power system can be integrated with a Go
Power! RV Solar Kit (sold separately by Go Power; please contact us directly.)
1. Plug in the power cord. If the main panel circuit breakers are switched on, RV load should operate normally. Unplug the
power cord.
2. Start the generator. There is a pre-programmed 20-30 second delay in the transfer switch. The delay is designed to allow
the generator a brief warm-up period. When the delay completes its cycle the switch should engage and the RV load
should operate normally. An audible click should sound as the switch engages.
3. Shut down the generator. As the generator winds down the switch should disengage without chatter or cycling. An audible
click should sound as the switch disengages.
4. Plug in the power cord. Start the generator. After the preprogrammed delay, the switch should transfer power automatically
from the power cord to the generator. Listen for the audible click as the switch transfers, as there will likely be no other
indication that the switch has engaged. Shut down the generator and unplug the power cord.
5. On transfer switch arrangements with three power supplies, plug in the power cord, start the generator, and turn on the
inverter. With all three supplies energized at the same time, the switch will select the generator for the primary supply choice.
Shut down the generator. The switch will transfer to the power cord. Unplug the power cord. The switch will transfer to
the inverter. The inverter should always be connected so that it is only selected in the absence of both the other supplies.
3. OPERATIONAL TESTING
The powercord is a 15, 20 or 30 amp line from
the main panel.
#1
#2