Go Power! Electric RV-10 Manual Download Page 10

10

www.gpelectric.com

3. Warranty repair and/or evaluation will be provided only at the Victoria, British

Columbia facility of Go Power Electric Inc. Units for such repair and/or evaluation

must be returned freight prepaid to Go Power Electric Inc. with a written description

of any apparent defects. An RMA # issued only by Go Power Electric Inc. must be

clearly visible on the outside of the returned package. Go Power Electric Inc. will

not be required at any time to visit the installation site wherein Go Power Electric

Inc. products are subject to warranty repair and/or evaluation.

4. Only Go Power Electric Inc. is authorized to repair any of its products, and they

reserve the right to repair or replace any unit returned for warranty repair. The

party returning a unit for repair is responsible for proper packaging and for shipping

and insurance charges, as well as any other charges encountered, in shipping to

and from Go Power Electric Inc.

5. The purchaser’s exclusive remedy for any and all losses or damages resulting from

the date of sale of this product including, but not limited to, any allegations of

breach of warranty, breach of contract, negligence or strict liability, shall be limited,

at the option of Go Power Electric Inc., to either the return of the purchase price or

the replacement of the particular product for which claim is made and proved.  In

no event shall Go Power Electric Inc. be liable to purchaser or purchaser’s customers

or to anyone else for any punitive, special, consequential, incidental or indirect

losses or damages resulting from the sale of the product, whether based upon loss

of goodwill, lost profits, work stoppages, impairments of other goods, breach of

contract, or otherwise.

6. This warranty supersedes all other warranties and may only be modified by statement

in writing, signed by Go Power Electric Inc.

7. Warranty terms effective as of January 2, 2004.

8.2  Repair and Return Information

To return items:

1. Call your Go Power Electric Inc. sales representative or Go Power Electric Inc.

Technical Support (1-866-247-6527) to try and troubleshoot the problem.

2. Obtain an RMA # through your Go Power Electric Inc. sales representative or Go

Power Electric Inc. Technical Support.

3. Ensure the RMA # is clearly visible on the outside of the package, or THE PACKAGE

WILL BE REFUSED.

4. Ship to Go Power Electric Inc. PREPAID at the following address:

CANADA

Go Power Electric Inc.

1969 Keating Cross Rd.

Victoria, BC V8M 2A4

5. Do not ship product collect, unless approved by management prior to Go Power

Electric Inc. receiving said product, or THE PACKAGE WILL BE REFUSED.

6. Test items or items that are not under warranty, or units that are not defective, will

be charged a minimum bench charge of $50.00 US plus taxes and shipping.

7. A 15% restocking charge will be applied on goods returned and accepted as “new”

stock.

USA

Go Power Electric Inc.

340 El Pueblo Rd. Suite F

Santa Cruz, CA 95060

RV Kit Installation

RV Kit Installation

RV Kit Installation

RV Kit Installation

RV Kit Installation

Summary of Contents for RV-10

Page 1: ... 80 GP RV102 110 115 GP RV160 GP RV240 GP RV50 55E GP RV80E GP RV102 110E US Contact Information Go Power Electric Inc 340 El Pueblo Rd Suite F Santa Cruz CA 95060 Tel 866 247 6527 Fax 866 607 6527 Email info gpelectric com Canadian Contact Information Go Power Electric Inc 1969 Keating Cross Rd Victoria BC V8M 2A4 Tel 866 247 6527 Fax 866 607 6527 Email info gpelectric com ...

Page 2: ... 6 2 4 RV 102 RV 110 RV 115 RV 204 RV 220 6 2 5 Expander Kits Using an Interconnect Cable 6 3 0 Wiring the RV 102 RV 110 RV 115 Kits 7 3 1 Wiring Two Solar Modules In Parallel with MC Cables 7 3 2 Modules with MC Connectors Wired to a Non Potted Junction Box 7 4 0 Routing Power Cable through the Fridge Vent 7 4 1 Method 1 Hole in Side of Vent 7 4 2 Method 2 Through Screen Grid 7 5 0 Mounting the S...

Page 3: ...r particular installation Kits with MC connectors will not include parts 04 and 07 Only kits with MC connectors and more than one module will include parts 05 and 06 RV Kit Installation RV Kit Installation RV Kit Installation RV Kit Installation RV Kit Installation 01 02 03 04 07 09 10 11 12 13 14 15 16 18 19 Solar Module GPR 22 A Regulator 20 Parts Checklist Battery not included 17 08 Optional 21...

Page 4: ...ately one volt the GPR 22 regulator will resume charging Please read and understand all instructions before installing your new product for the easiest and safest installation Before installing the kit please review the installation design included in this Installation Manual If you have any doubts as to this kit s sustainability or compatibility with your RV please contact your authorized Go Powe...

Page 5: ...V 10 Section 2 1 RV 50 55 Section 2 2 RV 80 Section 2 3 RV 102 110 115 Section 2 3 Weekender Section 2 3 RV 160 Section 2 4 RV 240 Section 2 4 Snowbird Section 2 4 Wiring Diagrams located at the end of the manual Junction Boxes Diagram 1 Wiring Single and Parallel Modules Diagram 2 Cable Extensions for MC Connectors Diagram 3 MC Connections for 1 2 Modules Diagram 4 2 1 RV 10 1 Remove the module s...

Page 6: ...gh the Fridge Vent 2 4 RV 160 RV 240 Snowbird Expander Kits Multipanel Using an Interconnect Cable 1 Strip 6 of outer sheathing from the power cable exposing positive red and negative black wires Do not nick wires 2 Remove the modules Junction Box covers Place the modules side by side glass down Remove the knockout on the Junction Box for the cable To remove the knockout on the Junction Box hold a...

Page 7: ...his case the MC cables may be ignored and the Junction box may be wired normally The MC cables may be removed or left in place as long as they do not impede the installation process Do not connect the positive and negative MC cables from the same junction box together this will short circuit the module 4 0 Routing Power Cable through the Fridge Vent Locate the refrigerator vent on the roof of the ...

Page 8: ...10 and Expander Kits The GPR 22 regulator provides the necessary protection for the RV battery system A condensed version of the installation instructions appear below however please read the full installation manual included with the GPR 22 regulator 1 Disconnect or cover the solar modules and disconnect the batteries before commencing the GPR 22 regulator wiring 2 Run the solar module power cabl...

Page 9: ...r installation including but not limited to improper environmental protection and improper hook up Acts of God including lightning floods earthquakes fire and high winds Damage in handling including damage encountered during shipment 2 This warranty shall be considered void if the warranted product is in any way opened or altered The warranty will be void if any eyelet rivets or other fasteners us...

Page 10: ... be liable to purchaser or purchaser s customers or to anyone else for any punitive special consequential incidental or indirect losses or damages resulting from the sale of the product whether based upon loss of goodwill lost profits work stoppages impairments of other goods breach of contract or otherwise 6 This warranty supersedes all other warranties and may only be modified by statement in wr...

Page 11: ...y or solar cell which flows in one direction The unit for current is ampere or amp for short and designated by the letter A Cycle One battery cycle equals one discharge and one charge Deep Cycle Battery Batteries that are designed to discharge as much as 80 of their capacity as opposed to engine starting or shallow cycle batteries which are designed for heavy cranking but will not stand up to repe...

Page 12: ...d all sides of the array fully exposed to the wind Open Circuit Voltage Voc Refers to a photovoltaic device s voltage potential when it is disconnected from the rest of the PV system Panel A group of photovoltaic modules or single module mechanically mounted on a single frame Parallel Connection Electrical connection where the positive terminals of a number of devices are connected together as are...

Page 13: ...d battery Normally used to refer to large sulfate crystals rather than small crystals formed in normal battery operation The sulfate on the plates of a battery will harden if left in a partially charged state causing reduced battery capacity and shortening the life of the battery If caught in time equalization will remove the buildup of sulfation Voltage The electrical potential between two points...

Reviews: