Page 5 of 15
Pressure Measurement Amplifier DMV 4000
5. Adjustment possibilities:
The following table lists the possibilities of parameter changes
=
conf
conf
conf
conf
Configuration menu
pass
pass
pass
pass
Code I
Configuration menu password
Input Range
base.c
base.c
base.c
base.c
FREQ
FREQ
FREQ
FREQ
Frequency of input voltage
50 / 60
INP
INP
INP
INP
UNiT
UNiT
UNiT
UNiT
Engineering units
Bar / PSI / Mpa
DP
DP
DP
DP
Number of decimals
0...3
FILT
FILT
FILT
FILT
IN 1 filter constant time
0...30 s
RAN.Lo
RAN.Lo
RAN.Lo
RAN.Lo
Low range
-9999...99999
RAN.Hi
RAN.Hi
RAN.Hi
RAN.Hi
High range
-9999...99999
A0
A0
A0
A0
AO.tYP
AO.tYP
AO.tYP
AO.tYP
Analogue Out Type
0-20 / 4-20
AO.Lo
AO.Lo
AO.Lo
AO.Lo
Analogue Out Low Range
-9999...99999
AO.Hi
AO.Hi
AO.Hi
AO.Hi
Analogue Out High Range
-9999...99999
sys
sys
sys
sys
Prot
Prot
Prot
Prot
Communications protocol
Modbus / Jbus
baUd
baUd
baUd
baUd
Baud rate
200...57600
ParY
ParY
ParY
ParY
Parity
none/euen/odd
Addr
Addr
Addr
Addr
Communications address
1...247
CodeI
CodeI
CodeI
CodeI
Password 1
0...65534
Co
Co
Co
Code2
de2
de2
de2
Password 2
0...65534
Code3
Code3
Code3
Code3
Password 3
0...65534
ALARM
ALARM
ALARM
ALARM
AL!.LT
AL!.LT
AL!.LT
AL!.LT
Reset by acknowledgement or external (IL1)
none / Ltch
AL2.LT
AL2.LT
AL2.LT
AL2.LT
Reset by acknowledgement or external (IL2)
none / Ltch
AL3.LT
AL3.LT
AL3.LT
AL3.LT
Reset by acknowledgement or external (IL3)
none / Ltch
0VT 1
0VT 1
0VT 1
0VT 1
Output action of alarm 1
direct / reverse
0VT 2
0VT 2
0VT 2
0VT 2
Output action of alarm 2
direct / reverse
0VT 3
0VT 3
0VT 3
0VT 3
Output action of alarm 3
direct / reverse
(AL
(AL
(AL
(AL
CAL.PT
CAL.PT
CAL.PT
CAL.PT
Shunt for strain gage cal.
50...100%
Ehit
Ehit
Ehit
Ehit
Exit Configuration menu