LiFTFORCE LPX 2.0 Operating Instructions

3

Figure 3

Figure 5

Figure 4

Figure 2

Figure 6

Do not open the battery. This can only be done by GNB service 
personnel. Only authorized GNB personnel are allowed to open 
the battery system. Otherwise warranty will be void. The user 
should verify the condition of all external cables and connections 
prior to each operation. Before carrying out any inspection of the
cables, the battery must be turned off and unplugged from the 
charger and the vehicle. In the case of any issues please contact 
your local service engineer.

ATTENTION:
Risk of damaged device

•   Never clean the system or system parts using a  

vapour jet or spray water. 

•   Dirt and water may enter the system and cause 

major damage.

•   Use only a moist and clean cotton cloth for cleaning.

Storage
Before being placed in storage the battery should be charged to 
50 % SOC charged and disconnected from both the vehicle and 
the charger. The LiFTFORCE LPX 2.0 Lithium Material Handling 
Battery system has a very low self-discharge and can be put into 
storage for up to 12 months. It must then be recharged If batter-
ies are taken out of service, they should be stored in a dry and 
frost free room. Please find the minimum and maximum storage
temperature in Table 1.

Display
The display indicates the State of Charge (SOC) of the battery
from 100 to 0%. The LED on the right of the gauge will flash
when SOC is low and will stay on as an indicator to the operator
to charge the battery. If the operator ignores this advice, the
battery will automatically shut down at 0% SOC. The wrench
symbol will flash if there is a battery fault. If this occurs, please
contact a GNB Service Engineer.
The advanced display can be seen in Figures 3, 4, 5, and 6 below.
This display shows more detailed information (Voltage, current,
max/ min Temperature, SOC, charge mode) and can be fitted
anywhere with a display mount.

BATTERY MAINTENANCE

Summary of Contents for Liftforce LPX 2.0

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS FOR LIFTFORCE LPX 2 0 LITHIUM ION BATTERY ...

Page 2: ... shock Do not lift or pull up on power or communication cables Avoid wearing any loose metallic items such as jewelry watches or bracelets Corrosive contents Do not open Avoid contact with contents of a damaged battery To avoid the release of harmful gases avoid deeply discharging charging when damaged and improperly charging the battery Use certified insulated safety tools for installation Any wo...

Page 3: ...t be accessible to operating and maintenance personnel at all times Each person given the task of operating or maintaining the system must have read and understood the instructions The health and safety information refers to the current directives of the European Union In other countries the relevant laws and regulations must be noted and followed Quick Start Guide Check the battery housing the ca...

Page 4: ...nate the charge cycle automatically After charging the vehicle can be put back into service immediately A rest phase or cooling is not required for the LiFTFORCE LPX 2 0 Lithium Material Handling Battery Warnings and Alarms An alarm buzzer will be active under following conditions Under Voltage Over Voltage Over current Under temperature Over temperature Communication error Safety line error Howev...

Page 5: ...rged to 50 SOC charged and disconnected from both the vehicle and the charger The LiFTFORCE LPX 2 0 Lithium Material Handling Battery system has a very low self discharge and can be put into storage for up to 12 months It must then be recharged If batter ies are taken out of service they should be stored in a dry and frost free room Please find the minimum and maximum storage temperature in Table ...

Page 6: ... or Opus A3 Figure 3 Weight See battery label Notes Discharge If the internal battery temperature falls below 4ºF 20ºC the battery will disconnect If the battery internal temperature reaches 140ºF 60ºC the battery will disconnect Derating message is transmitted at 131ºF 55ºC Charge Charging is forbidden below an internal battery temperature of 32ºF 0ºC If the battery internal temperature reaches 1...

Reviews: