LiFTFORCE LPX 2.0 Operating Instructions
2
Figure 1
Charging
The LiFTFORCE LPX 2.0 Lithium Material Handling Battery may
only be charged with an GNB certified battery charger.
Please also refer to the Installation and Operating Instructions for
the GNB certified battery charger.
To extend battery life we recommend charging at each oppor-
tunity which means each break e.g. lunch, coffee etc. This will
increase the battery life time and your productivity.
The LiFTFORCE LPX 2.0 Lithium Material Handling Battery system
is charged as follows:
Bring the vehicle to the GNB certified battery charger.
Check that all cables and plug-in connections are in working
condition.
For batteries featuring the Easy Charge option, the vehicle
is electrically disconnected from the GNB battery system
during charging.
If battery is needed before charging is complete, press the stop
button on the charger before disconnecting.
GNB certified chargers are equipped to control and terminate
the charge cycle automatically. After charging, the vehicle can
be put back into service immediately. A rest phase or cooling
is not required for the LiFTFORCE LPX 2.0 Lithium Material
Handling Battery.
Warnings and Alarms
An alarm buzzer will be active under following
conditions:
• Under Voltage
• Over Voltage
• Over current
• Under temperature
• Over temperature
• Communication error
• Safety line error
However, if the above mentioned warnings continue, the Battery
Management System will shut down the battery. If this occurs,
please push the on/off button to drive to the charger. If driving is
no longer possible, stop working and contact GNB service.
INSTALLATION/OPERATION, CONTINUED
On / Off button
LED Green
LED Red
System in Standby mode
Off
Off
System active, no alarm or
warning detected
1 in 5 seconds
Off
Warning
Off
1 in 1 second
Alarms
Off
3 in 1 second
Button pressed for less than 5 s to Reset
Warnings / Alarms
On as long as button is pressed
Off
Button pressed for more than 5 s to move
from active to Standby mode
Off
On as long as button is pressed
Button is pressed in standby mode and
the system is moved into active mode.
On as long as button is pressed
Off