GNB Liftforce LPX 2.0 Installation And Operating Instructions Manual Download Page 3

LiFTFORCE LPX 2.0 Operating Instructions

1

GENERAL INFORMATION

INSTALLATION/OPERATION

SAFETY

Thank you for choosing a LiFTFORCE LPX 
2.0 Lithium Material Handling Battery. This 
battery system is completely self-contained 
and can be used as a direct replacement 
for the most current in-use lead acid and 
lithium-ion systems.

Scope of supply
The following parts are included in the 
scope of supply:

•   LiFTFORCE LPX 2.0 Lithium Material  

Handling Battery Documentation  
(installation and operation manual)

•   External display (optional)
•   GNB Charger (optional)

After unpacking the parts, please examine 
them for possible damage. If any damage is 
found, please do not use the product; if in 
doubt, please contact the manufacturer.
The described product is a Lithium 
rechargeable battery system for use in 
material handling applications.

General Safety Instructions
Information and instructions attached directly on the LiFTFORCE 
LPX 2.0 Lithium Material Handling Battery system must always be 
followed. These instructions contain basic information and guid-
ance to be noted and followed during operation and maintenance 
and must be read by all personnel. 

The GNB Lithium-ion battery system may not be operated without 
precise knowledge of these Installation and Operating Instructions 
or without strict adherence to all safety instructions. Knowledge 
of the contents of the Installation and Operating manual is a 

fundamental requirement to protect people from danger, to avoid 
errors and to operate the system safely and fault-free. 

The Installation and Operating Instructions must
be accessible to operating and maintenance personnel at all 
times. Each person given the task of operating or maintaining the 
system must have read and understood the instructions. 

The health and safety information refers to the current directives 
of the European Union. In other countries the relevant laws and 
regulations must be noted and followed:

Quick Start Guide

•   Check the battery housing, the cables and connectors  

for damages.

•   Switch the battery on by pressing the ON/ OFF button for 

one second, observe the button. 

•   In normal operation the button flashes green once in 5 

seconds. Flashing red color indicates a warning or failure 
state. Please refer to the section Warning and Alarms in 
this case. 

•   At the delivery state the battery SOC display should  

indicate an SOC of 30—50% 

•  The battery must be fully charged prior to first usage. 

The LiFTFORCE LPX 2.0 Lithium Material Handling Battery  
communicates status to the vehicle via the CAN bus or to  
the operator via an external GNB display.

Deep Discharge Protection
When charge level is low, the buzzer pulses steadily. The
battery must be charged immediately. The battery will turn
off if deeply discharged.

WARNING:
Deep discharge should be avoided at all costs as the sudden 
cut off of the battery can lead to damage and hazards, such as 
spontaneous stop of the vehicle.
The reset button can be pressed once to get the vehicle to the 
charger. After that, the battery remains turned off in order to 
avoid further damage. The vehicle now has to be towed to the 
charge with auxiliary means.

ATTENTION:
If the battery has shut off due to a low discharge level, it must 
be charged immediately. Long shelf times of discharged batter-
ies are to be avoided at all costs! (see Storage) Non-observance 
can lead to battery damage.

Summary of Contents for Liftforce LPX 2.0

Page 1: ...INSTALLATION AND OPERATING INSTRUCTIONS FOR LIFTFORCE LPX 2 0 LITHIUM ION BATTERY ...

Page 2: ... shock Do not lift or pull up on power or communication cables Avoid wearing any loose metallic items such as jewelry watches or bracelets Corrosive contents Do not open Avoid contact with contents of a damaged battery To avoid the release of harmful gases avoid deeply discharging charging when damaged and improperly charging the battery Use certified insulated safety tools for installation Any wo...

Page 3: ...t be accessible to operating and maintenance personnel at all times Each person given the task of operating or maintaining the system must have read and understood the instructions The health and safety information refers to the current directives of the European Union In other countries the relevant laws and regulations must be noted and followed Quick Start Guide Check the battery housing the ca...

Page 4: ...nate the charge cycle automatically After charging the vehicle can be put back into service immediately A rest phase or cooling is not required for the LiFTFORCE LPX 2 0 Lithium Material Handling Battery Warnings and Alarms An alarm buzzer will be active under following conditions Under Voltage Over Voltage Over current Under temperature Over temperature Communication error Safety line error Howev...

Page 5: ...rged to 50 SOC charged and disconnected from both the vehicle and the charger The LiFTFORCE LPX 2 0 Lithium Material Handling Battery system has a very low self discharge and can be put into storage for up to 12 months It must then be recharged If batter ies are taken out of service they should be stored in a dry and frost free room Please find the minimum and maximum storage temperature in Table ...

Page 6: ... or Opus A3 Figure 3 Weight See battery label Notes Discharge If the internal battery temperature falls below 4ºF 20ºC the battery will disconnect If the battery internal temperature reaches 140ºF 60ºC the battery will disconnect Derating message is transmitted at 131ºF 55ºC Charge Charging is forbidden below an internal battery temperature of 32ºF 0ºC If the battery internal temperature reaches 1...

Reviews: