Leakage
If LPG leakage is detected or suspected, the following action should be taken immediately.
Shut off the LPG supply at the cylinder valve(s).
Extinguish naked flames and other ignition sources(heaters,cooking appliances, pilot lights,
cigarettes etc).
Do not operate electric switches.
Ventilate the area with a through draught.
Evacuate the area if possible.
If leakage is from a cylinder and cannot be stopped, move the cylinder to where LPG can disperse
away from the vessel (and other vessels). Take care not to spill LPG while moving the cylinder.
Do not use an installation that has leaked until it has been checked by a competent person.
Fire from an LPG leak
If an LPG leak has ignited, action should be taken in accordance with (a) or (b) as appropriate.
If the vessel is moored:
Alert everyone in the area and evacuate if possible.
Call the fire brigade, if practicable.
Do not attempt to extinguish any flame unless it is safe to do so. Shut off the LPG supply
before attempting to extinguish the flame. After shutting off the LPG supply, extinguish any
free burning materials with extinguishers or water.
Do not reuse the installation unless it has been checked by a competent person.
If the vessel is off shore:
Alert everyone on the vessel.
If it is safe to do so, shut off the gas supply.
Extinguish any free burning material with extinguishers or water.
Do not reuse the installation unless it has been checked by a competent person.
Fire close to an LPG cylinder:
WARNING:
Cylinders exposed to fire can explode.
If there is a fire near to an LPG cylinder, the following action should be taken.
Alert everyone in the area and evacuate if possible.
Call the fire brigade if practicable.
If it is safe to do so, shut off the gas supply and move the cylinder to a safe place in the open.
If the
cylinder cannot be moved, keep it cool with wet blankets and spraying with water.
Do not reuse the installation unless it has been checked by a competent person.
ANNEX B
Safe usage : Changing a cylinder
The following safe practices should be complied with when changing a cylinder.
(1) Ensure that any manually operated valves on both the full and empty cylinder are turned off
before changing. Replace the plastic safety cap or plug on disconnected cylinders.
(2) Store, transport and use cylinders vertically with the valve uppermost.
(3) Do not use a cylinder if the cylinder, valve or regulator are damaged. Return the cylinder to
the supplier. Do not attempt to repair the fault.
(4) Before changing the cylinder, extinguish any fire, flame or source of ignition, including
cigarettes and pilot lights.